- 0:00Good diode to everyone and welcome to
- 0:01Atilab. With four experiments, I will
- 0:04show you how rectifier circuits and
- 0:06diode bridges work. Bridge. The diodes
- 0:15I chose for this experiment are the
- 0:17classic 1N4007. And to think they were
- 0:22just 70V, though in reverse polarity;
- 0:24they are generic silicon diodes with a
- 0:271000V reverse voltage. I set up the
- 0:30test bench with the oscilloscope, the
- 0:32RS Pro waveform generator, and here the
- 0:34breadboard with the small circuit
- 0:36featuring one diode and one resistor.
- 0:39Very simple. All that remains is to
- 0:41connect the oscilloscope probes and
- 0:43activate the waveform generator output.
- 0:46The diagram of the first experiment I'm
- 0:48presenting is a half-wave rectifier
- 0:50with a diode and a load resistor.
- 0:53Channel 2 of the oscilloscope will
- 0:55measure the output voltage of the
- 0:57circuit, which is measured across
- 0:58resistor R1. An extremely important
- 1:06thing before turning on the waveform
- 1:09generator output, besides having set
- 1:12parameters like amplitude and frequency
- 1:15—in this case 50 Hz—is to remember
- 1:19to set the waveform generator output to
- 1:22high impedance mode and not 50-ohm
- 1:25coupling. And look at it here. We have
- 1:30our waveform, which is, in fact, the
- 1:32classic one for a single-wave rectifier
- 1:34. In fact, we see the input sine wave,
- 1:37which is complete, and the
- 1:39half-rectified sine wave at the output,
- 1:41which is missing a part—specifically,
- 1:43the negative part. Furthermore, you can
- 1:47also slightly see the voltage drop
- 1:49caused by the diode here, in this case
- 1:52about 0.7 V. The next experiment
- 1:54consists of connecting a small 4.7
- 1:56microfarad capacitor in parallel to the
- 1:59resistor. And look at how the waveform
- 2:03on the oscilloscope changes. There you
- 2:05go, this is a rectifier with a
- 2:07capacitive filter. The diagram of the
- 2:09half-wave rectifier with a capacitive
- 2:11filter is identical to the previous one
- 2:13, so there is a diode and a load
- 2:15resistor, and the VO is still read by
- 2:17channel 2. In this case, however, a 4.7
- 2:20microfarad capacitor C1 is added in
- 2:23parallel to the load resistor. Because
- 2:26of the capacitor, we get this smoothing
- 2:28of the positive half-wave, and if you
- 2:30look, a certain residual ripple remains
- 2:33, which is precisely called "ripple"—
- 2:35a very slight variation that is
- 2:37superimposed on a continuous average
- 2:39value. The very interesting thing I can
- 2:43do thanks to the waveform generator is
- 2:45to change the frequency, and look at
- 2:47what happens if I lower the frequency.
- 2:51Now we are at 10 Hz. Look at the
- 2:54residual ripple and how it has
- 2:56increased. In fact, the ripple is truly
- 2:59a function not only of the resistance
- 3:01and load capacity of the rectifier but
- 3:03also of the frequency, and with this
- 3:05experiment, you can see it very clearly
- 3:07. The schematic for the third
- 3:10experiment is a full-wave rectifier,
- 3:12also known as a Graetz bridge, which
- 3:14consists of a bridge of four diodes. In
- 3:17this case as well, the load resistor is
- 3:19100k ohms, and the output is measured
- 3:21across the load resistor. But before
- 3:25building an actual diode bridge, I will
- 3:27show you how diode bridges work using
- 3:29the waveform generator and an LED diode
- 3:31bridge. And look, I can go ahead and
- 3:35reduce the sine wave frequency using
- 3:37the waveform generator. I'll lower it
- 3:40slowly, and you will see the LEDs start
- 3:43to flicker until, at a certain point,
- 3:45you can see the diode bridge
- 3:47functioning as intended. And there it
- 3:50is. Look, the LEDs alternate in pairs.
- 3:54When the input voltage half-wave is
- 3:56positive, one pair of diodes activates,
- 3:59and when the voltage half-wave is
- 4:01negative, the other pair activates.
- 4:04This way, the current within the
- 4:06resistor I mounted on the breadboard
- 4:09will always be positive and will always
- 4:11flow in one direction, from the
- 4:13positive red pole to the negative black
- 4:16pole. I also assembled the diode bridge
- 4:19circuit; as you can see, there are four
- 4:22diodes in this circuit. Now, in order
- 4:25to be analyzed with an oscilloscope, it
- 4:27requires some precautions. In fact, two
- 4:30probes are necessary to measure the
- 4:31output voltage. Looking at the diagram
- 4:35for a moment, it is clear that using a
- 4:36single probe, for example from channel
- 4:382 of the oscilloscope,
- 4:42would create a common ground connection
- 4:44between the oscilloscope and the
- 4:46waveform generator, which would
- 4:48short-circuit the diodes in the bridge
- 4:50and, consequently, the rectifier would
- 4:52no longer function correctly. It is
- 4:55therefore necessary to perform a
- 4:57differential measurement using two
- 4:58oscilloscope channels that will then be
- 5:00subtracted—in this case, channel 2
- 5:02and channel 3. Having connected the
- 5:05probes to the diode bridge circuit, I
- 5:07can now safely enable the waveform
- 5:09generator output and look at the waves
- 5:12presented on the oscilloscope. And as
- 5:15you can see, the rectified sine wave
- 5:17does not appear yet because you only
- 5:19see channel 2 and channel 3. To obtain
- 5:23the rectified sine waveform, you need
- 5:25to activate the math function and,
- 5:27specifically, perform channel 2 minus
- 5:29channel 3. Now, I will also set the
- 5:32correct division values so that it is
- 5:34clearly visible on the screen. And here
- 5:38we are. As you can see, the rectified
- 5:42sine wave is now actually being shown,
- 5:44which is naturally slightly lower than
- 5:47the input sinusoidal voltage, but also
- 5:49lower than the rectified voltage of
- 5:52just the positive or just the negative
- 5:54branch, because in this case, we
- 5:57naturally have twice the voltage drop
- 5:59across the diodes; so, two times 0.7,
- 6:02we have about 1.4 volts of voltage drop
- 6:04. Naturally, there is also the
- 6:07full-wave rectifier with a capacitive
- 6:10filter, which sees the addition to the
- 6:12previous diode bridge circuit of a 4.7
- 6:14microfarad capacitor in parallel with
- 6:17the load resistor. I have also
- 6:19connected the small 4.7 microfarad
- 6:21capacitor to the circuit. I turn on the
- 6:25output and ta-da. Here it is, our
- 6:28rectified and smoothed waveform thanks
- 6:30to the capacitive smoothing filter we
- 6:31inserted. In this case too, if I change
- 6:35the frequency, we have an increase in
- 6:38ripple. This time, however, it is
- 6:42definitely more reduced than before
- 6:44because in this case, we are rectifying
- 6:47both half-waves of the input sine wave.
- 6:50To see the effect of an increase in
- 6:53ripple, what you can do is reduce the
- 6:55load resistance. In this case, I have
- 6:58100 kOhms and I am going to place a 10
- 7:00kOhm resistor in parallel to the 100
- 7:02kOhms, which is effectively 1/10th. And
- 7:05look what happens when connecting the
- 7:07resistor. You see the natural increase
- 7:11in ripple, and this is due to having
- 7:12reduced the resistance because,
- 7:14naturally, the contribution of the load
- 7:16resistance is also present in the
- 7:18ripple formula. With this last
- 7:21experiment, I want to quantify the
- 7:23input current and in particular the
- 7:25peaks due to the capacitive filter. To
- 7:28do this, I will use a shunt resistor
- 7:30that should not modify the circuit's
- 7:32behavior with a relatively low value,
- 7:34and furthermore, it will allow me to
- 7:36measure the voltage across it and
- 7:38therefore, by applying Ohm's law,
- 7:39obtain the current flowing through it.
- 7:42I am indeed connecting it on the
- 7:44negative branch precisely to measure
- 7:46the input current; I have modified the
- 7:48circuit following the diagram and
- 7:50therefore added the 10-ohm shunt
- 7:52resistor I chose. In fact, the circuit
- 7:56has a 100 kOhm load, and the 10-ohm
- 7:57shunt resistor will certainly not
- 7:59influence the circuit itself, but it
- 8:01will allow me to measure the current
- 8:03flowing, let's say, on the negative
- 8:05branch. So, all that remains is, as
- 8:09always, to activate the waveform
- 8:11generator output and activate the
- 8:13oscilloscope reading on channel 4,
- 8:15which is the one measuring the current
- 8:17and which I have preset to read 200
- 8:19microamps per division. As you can see,
- 8:23the classic peaks due to the capacitive
- 8:25filter downstream of the rectifier
- 8:27bridge are present, and in particular,
- 8:29you can see that there is a positive
- 8:31peak and a negative peak. In this case,
- 8:34the current peak reaches 500 microamps,
- 8:37whereas the current reaching the load
- 8:39resistor alone, given that the
- 8:41rectified voltage is about 4 V, will be
- 8:43just 40 microamps. The peaks, therefore
- 8:47, are 10 times higher than the current
- 8:49reaching the load. These peaks are
- 8:52normal in the case of a rectifier with
- 8:53a capacitive filter, precisely because
- 8:55they must charge the capacitor in a
- 8:57short time, while the capacitor will
- 8:59then discharge much more slowly into
- 9:01the load resistor. For this video, I
- 9:04must certainly thank RS, which with its
- 9:06RS Pro product line provides a great
- 9:08deal of electronic laboratory equipment
- 9:10that is truly always top-notch. I have
- 9:14the waveform generator, oscilloscope,
- 9:16and a multimeter here, but you can find
- 9:18a lot more on their site, and remember
- 9:20that in the links in the description,
- 9:21you can get a 10%discount code. With
- 9:26this video, I tried to show you some
- 9:28experiments involving diode circuits,
- 9:30particularly half-wave and full-wave
- 9:32rectifiers, and above all, to show you
- 9:34practical measurements with the
- 9:35oscilloscope and the waveform generator
- 9:37. I remind you that it is only thanks
- 9:41to you that I can carry out these
- 9:43fantastic projects, so a thank you is
- 9:45absolutely due, and please, continue to
- 9:47support the AILAB channel with a
- 9:49comment below, by visiting the social
- 9:51pages Patreon, Telegram, Instagram, and
- 9:53Facebook where you can find constant
- 9:55updates on the activities I carry out
- 9:57in my small laboratory. And if you
- 10:00haven't already done so, subscribe to
- 10:01the AILAB channel, and in the meantime,
- 10:03cheers. Ciao.
About this transcript
This page contains the full transcript of Misure con Oscilloscopio per Capire i Raddrizzatori a Diodi - Elettronica di Base in 5 Minuti n14 by AT Lab, generated from the public captions YouTube serves with the video. The transcript has 1,567 words across 245 segments, with the original timestamps preserved so you can click any line to jump to that moment in the embedded player.
What you can do with it
Use the transcript to take notes, quote the speaker, build a study guide, generate a summary with ChatGPT or Claude via the YouTube Summary tool, or export it as a timed subtitle file with YouTube to SRT. You can also re-open it in the transcriber to choose a caption track available on the video.
Free YouTube transcript tool
YouTube2Text is a free YouTube transcript generator — no signup, no daily limit. Paste any YouTube link and get the full transcript instantly, with timestamps, click-to-jump, caption language selection, AI prompts for ChatGPT, Claude, and Gemini, and exports to TXT, SRT, VTT, or Markdown.