  1. 0:00Welcome back to the Master Pump Curve
  2. 0:02series. In episode 1, we discussed
  3. 0:05shutoff head. Today, we will understand
  4. 0:07impeller diameter, which is very
  5. 0:10important when reviewing a centrifugal
  6. 0:11pump curve.
  7. 0:13When you open a manufacturer's pump
  8. 0:14curve, you may see three different
  9. 0:16impeller diameters. In our example, the
  10. 0:19maximum is 10.50 in. Selected is 10.31
  11. 0:24in, and minimum is 8.00 in.
  12. 0:27So, why does one pump show three
  13. 0:30diameters? Which one should we use?
  14. 0:32Which curve represents the actual pump?
  15. 0:35And where should we plot our duty point?
  16. 0:37Understanding these questions is
  17. 0:39critical, because selecting the wrong
  18. 0:41impeller curve can result in incorrect
  19. 0:43pump selection. First, remember that the
  20. 0:46same centrifugal pump can often be
  21. 0:48supplied with different impeller
  22. 0:49diameters. The impeller is the rotating
  23. 0:52component that transfers energy to the
  24. 0:54liquid. When the diameter changes, the
  25. 0:57pump's performance also changes.
  26. 0:59The maximum diameter, 10.50 in, is the
  27. 1:03largest impeller, and generally provides
  28. 1:05the highest head and flow.
  29. 1:07The selected diameter, 10.31 in, is the
  30. 1:10actual impeller intended to be installed
  31. 1:13in the pump. Therefore, this is the most
  32. 1:15important curve for our pump analysis.
  33. 1:18The minimum diameter, 8.00 in,
  34. 1:21represents the lower end of the
  35. 1:23manufacturer's stated trimming range.
  36. 1:25So, maximum shows the upper performance,
  37. 1:28minimum shows the lower trim limit, and
  38. 1:30selected represents the actual pump
  39. 1:32configuration. Now, let's look at a
  40. 1:34common pump selection mistake.
  41. 1:37Suppose your calculated duty point
  42. 1:39requires a particular flow and head.
  43. 1:42When you look at the pump curve, the
  44. 1:43duty point may appear to fall nicely on
  45. 1:45the maximum 10.50 in curve.
  46. 1:49But if your actual selected impeller is
  47. 1:5110.31 in, the pump will not operate
  48. 1:54according to the 10.50 in curve.
  49. 1:57For example, if your duty point is 500
  50. 2:00GPM at 340 feet of head and the selected
  51. 2:03impeller is 10.31 inches, you must check
  52. 2:06that duty point on the 10.31 inch
  53. 2:09selected curve.
  54. 2:10So, don't simply say the duty point is
  55. 2:13on the pump curve.
  56. 2:14Always ask, which pump curve and which
  57. 2:17impeller diameter does it represent?
  58. 2:19When reviewing a pump curve, follow a
  59. 2:21simple process. First, identify the
  60. 2:24maximum, selected, and minimum impeller
  61. 2:27diameters. Second, locate the selected
  62. 2:30diameter curve because this represents
  63. 2:32the actual impeller.
  64. 2:34Third, plot your required duty point on
  65. 2:36the selected curve and verify that the
  66. 2:38required flow and head are achieved. The
  67. 2:41three curves also help us understand the
  68. 2:43pump's available adjustment range. The
  69. 2:45minimum diameter can be useful if future
  70. 2:48system changes require impeller
  71. 2:49trimming.
  72. 2:50However, [snorts] never assume that any
  73. 2:52diameter can be used. Always follow the
  74. 2:55manufacturer's pump curve and approved
  75. 2:57pump data.
  76. 2:58Let's summarize the key point.
  77. 3:00When a pump curve shows three impeller
  78. 3:02diameters, don't think of them as three
  79. 3:05different pumps. They represent
  80. 3:06different performance configurations of
  81. 3:08the same pump.
  82. 3:10The maximum diameter represents the
  83. 3:12highest performance configuration. The
  84. 3:14minimum diameter represents the lower
  85. 3:16end of the stated trim range. But, the
  86. 3:18selected diameter represents the actual
  87. 3:20impeller installed in the pump.
  88. 3:23So, whenever you receive a pump curve,
  89. 3:25ask three questions. What is the maximum
  90. 3:27diameter? What is the selected diameter?
  91. 3:30And where does my duty point fall on the
  92. 3:32selected curve?
  93. 3:34Remember, don't select the curve first
  94. 3:36and then justify the pump. First,
  95. 3:38understand the pump configuration,
  96. 3:40identify the selected impeller, and then
  97. 3:42verify the duty point.
  98. 3:44In the next episode, we will discuss
  99. 3:46MCSF, minimum continuous stable flow.

About this transcript

This page contains the full transcript of Master Pump Curves EP-2 | Impeller Diameter Explained | Complete 8-Part Series by MEP Engineering Insight, generated from the public captions YouTube serves with the video. The transcript has 564 words across 99 segments, with the original timestamps preserved so you can click any line to jump to that moment in the embedded player.

What you can do with it

Use the transcript to take notes, quote the speaker, build a study guide, generate a summary with ChatGPT or Claude via the YouTube Summary tool, or export it as a timed subtitle file with YouTube to SRT. You can also re-open it in the transcriber to choose a caption track available on the video.

Free YouTube transcript tool

YouTube2Text is a free YouTube transcript generator — no signup, no daily limit. Paste any YouTube link and get the full transcript instantly, with timestamps, click-to-jump, caption language selection, AI prompts for ChatGPT, Claude, and Gemini, and exports to TXT, SRT, VTT, or Markdown.