  1. 0:00Welcome to the pump curve basic series.
  2. 0:03This is an eight episode series where we
  3. 0:05break down critical pump curve
  4. 0:06parameters.
  5. 0:08Each episode is designed to help
  6. 0:09engineers understand essential pump
  7. 0:12concepts.
  8. 0:13Today we are covering the very first
  9. 0:15topic, shutoff head. In today's
  10. 0:17two-minute lesson, I'll show you where
  11. 0:19to find shutoff head on a pump curve and
  12. 0:21explain why every engineer should check
  13. 0:24it before selecting a pump.
  14. 0:27Have you ever wondered what happens if
  15. 0:29every valve downstream of a running pump
  16. 0:31is suddenly closed? Does the pressure
  17. 0:33continue rising forever?
  18. 0:35Surprisingly, it doesn't.
  19. 0:38What happens if you close all the valves
  20. 0:40while the pump is running? Does the
  21. 0:41pressure keep increasing forever?
  22. 0:44No. The pump reaches its maximum
  23. 0:46pressure, called the shutoff head.
  24. 0:49Understanding shutoff head is important
  25. 0:51to ensure your pipes, valves, and
  26. 0:53equipment can safely handle the maximum
  27. 0:55pressure the pump can produce.
  28. 0:58Shutoff head is the maximum pressure a
  29. 1:01centrifugal pump can produce when flow
  30. 1:03is zero. On a pump performance curve,
  31. 1:06this point is always located at the
  32. 1:08extreme left side where the flow is
  33. 1:10zero.
  34. 1:11The pump is still running, but the
  35. 1:13liquid cannot flow. So, the impeller's
  36. 1:16energy mainly builds up as pressure.
  37. 1:18That is why the shutoff point represents
  38. 1:21the maximum head the pump can produce.
  39. 1:25Suppose a pump is designed for 500 GPM
  40. 1:28at 340 ft head. When the discharge valve
  41. 1:31is fully closed, the pump may develop
  42. 1:34430 ft head.
  43. 1:36That means the system pressure becomes
  44. 1:37much higher than during normal
  45. 1:39operation.
  46. 1:40So, the pipes, valves, flanges, and
  47. 1:43gauges must be rated for this maximum
  48. 1:45pressure.
  49. 1:46430 ft versus 340 ft equals about 26%
  50. 1:51higher head.
  51. 1:52That is why we must always check the
  52. 1:54shutoff head against the maximum
  53. 1:56allowable pressure of the system.
  54. 1:59Follow these three simple checks.
  55. 2:01Find the shutoff head at zero flow on
  56. 2:04the pump curve.
  57. 2:05Compare it with the pressure ratings of
  58. 2:07pipes, valves, fittings, tanks, and
  59. 2:10other equipment.
  60. 2:11Check the relief valve setting to
  61. 2:13prevent overpressure.
  62. 2:15Always keep a safe margin between the
  63. 2:17shutoff head and the equipment rating.
  64. 2:19This simple check can help prevent
  65. 2:21equipment failure and improve system
  66. 2:23safety.
  67. 2:25Let's quickly recap today's lesson.
  68. 2:27Shutoff head is the maximum pressure a
  69. 2:30centrifugal pump can develop at zero
  70. 2:32flow, and it is always located at the
  71. 2:34left end of the pump performance curve.
  72. 2:37Before selecting or approving any pump,
  73. 2:40always compare this value with the
  74. 2:41pressure rating of your system and
  75. 2:43ensure proper relief valve protection.
  76. 2:46In the next episode, we'll learn why the
  77. 2:48selected impeller diameter is far more
  78. 2:50important than the maximum impeller
  79. 2:52shown on the pump curve, and how
  80. 2:54choosing the wrong curve can lead to
  81. 2:55incorrect pump selection.
  82. 2:57Don't forget to like, subscribe, and
  83. 2:59share this series with fellow engineers.
  84. 3:01See you in episode two.

About this transcript

This page contains the full transcript of Master Pump Curves | EP-1 What is Shut-Off Head? | Complete 8-Part Series by MEP Engineering Insight, generated from the public captions YouTube serves with the video. The transcript has 468 words across 84 segments, with the original timestamps preserved so you can click any line to jump to that moment in the embedded player.

What you can do with it

Use the transcript to take notes, quote the speaker, build a study guide, generate a summary with ChatGPT or Claude via the YouTube Summary tool, or export it as a timed subtitle file with YouTube to SRT. You can also re-open it in the transcriber to choose a caption track available on the video.

Free YouTube transcript tool