How a CIP System from CSI Works! | CIP Overview — Transcript
Full transcript
- 0:01[Music]
- 0:07I am Trent Bullock, director of
- 0:09engineering for CSI. Just kind of have a
- 0:12variety of CIP skids here in various
- 0:15stages of factory acceptance testing.
- 0:17And so we thought it would be a good
- 0:18idea to kind of do a general overview of
- 0:20CIP and kind of just show you some
- 0:22things that are common on CIP systems
- 0:24that continuously roll through our shop.
- 0:27So right here we have a custom CIP
- 0:30system that's based on our CIP 2.0
- 0:33controls technology. This one's a fairly
- 0:35small uh two-tank system. Few of the
- 0:38safety things I like to go over on these
- 0:40systems is as every system will have an
- 0:42estop on it. So if you're in a wash and
- 0:43something's going going wrong, you can
- 0:45esop that and abort any washes, drive
- 0:48everything to a safe condition. If you
- 0:50need to lock up the power to do any
- 0:52maintenance on your CIP system, we have
- 0:54a lockable disconnect on the door. And
- 0:56then around around the corner here, we
- 0:58have our OSHA dump valve to basically
- 1:00lock out the air.
- 1:05Other things on this system, this one
- 1:07has automatic chemical dosing for costic
- 1:09acid and sanitizer. So in this case,
- 1:12we're using two Wen double diaphragm
- 1:14pumps for costic and acid and then a
- 1:16parastoaltic pump for sanitizer. Two
- 1:19tanks in this case. So we'll have a
- 1:21dedicated rinse tank and then a common
- 1:24chemical tank. So we'll use that tank
- 1:26for costic and acid in this particular
- 1:28configuration.
- 1:31[Music]
- 1:36So one of the uniqueness things on this
- 1:38particular system is the the use of the
- 1:40LKH prime. We have an LK prime here on
- 1:43the CIP return. The prime is really good
- 1:45when you have a lot of entrained air
- 1:47like you will see uh when you're doing
- 1:49CIP return of of cleaning a tank where
- 1:51you generally don't want a lot of liquid
- 1:52level.
- 1:57So the CIP return will come back through
- 1:59a variety of automated valves. We'll
- 2:01have conductivity and temperature
- 2:03measurements as well as proof of flow.
- 2:05So that proof of flow ensures that the
- 2:08entire circuit is established and we can
- 2:10use that for safety interlocks against
- 2:12steam, chemicals, things of that nature.
- 2:16[Music]
- 2:18All systems will have water supply. You
- 2:21could have just city water, you could
- 2:23have DI water, you could have hot and
- 2:25cold water if you want to have a little
- 2:26bit quicker heat up times on your CIP.
- 2:29And then all systems will have multiple
- 2:31drain locations. In this case, we
- 2:33actually have both drains uh piped to a
- 2:35single location, but you'll have a high
- 2:38flow drain for all your rinse steps. And
- 2:40then you'll have a common header drain
- 2:42for draining of tanks in between phases
- 2:45or for maintenance purposes.
- 2:49[Music]
- 2:54So, for just an example, I'll I'll show
- 2:56you how simple it is to uh start a wash
- 2:58on our CF 2.0 controls. This one's
- 3:01already been configured for the system.
- 3:02So, we'll just pick a simple wash here.
- 3:05So, we'll go up to commands and we'll
- 3:07pick a circuit. So, in this case, we're
- 3:09just in test mode. So, we'll pick
- 3:11circuit one. And we'll say our swing
- 3:13connections are complete. And then
- 3:14you're presented with the washes you can
- 3:16pick. So, we have five dedicated washes
- 3:18uh on these systems by default. And I'm
- 3:20just going to pick something simple.
- 3:21We'll do the sanitizer only wash. All
- 3:24right. So, once the system starts, you
- 3:25can hear it kick on. And you close it
- 3:27out. You can kind of see the status of
- 3:29the system. Pump is ramping up.
- 3:32Sanitizer is dosing.
- 3:35So in this case, the wash is completed
- 3:38successfully and so the skid's uh
- 3:40shutting everything down and basically
- 3:41going back to an idle state. So yeah,
- 3:43just that easy.
- 3:45[Music]
- 3:48Well, thanks for spending a little time
- 3:50with us here um at CSI. And if you have
- 3:52any questions, feel free to give us a
- 3:54call. If you have a CIP application we
- 3:56can help you with, there's plenty of
- 3:58people on the other end of the line.
- 3:59Would love to talk to you. Thanks.
- 4:01[Music]
About this transcript
This page contains the full transcript of How a CIP System from CSI Works! | CIP Overview by Central States Industrial, generated from the public captions YouTube serves with the video. The transcript has 695 words across 104 segments, with the original timestamps preserved so you can click any line to jump to that moment in the embedded player.
What you can do with it
Use the transcript to take notes, quote the speaker, build a study guide, generate a summary with ChatGPT or Claude via the YouTube Summary tool, or export it as a timed subtitle file with YouTube to SRT. You can also re-open it in the transcriber to choose a caption track available on the video.
Free YouTube transcript tool
YouTube2Text is a free YouTube transcript generator — no signup, no daily limit. Paste any YouTube link and get the full transcript instantly, with timestamps, click-to-jump, caption language selection, AI prompts for ChatGPT, Claude, and Gemini, and exports to TXT, SRT, VTT, or Markdown.