EIA TIA Wiring Standards — Transcript

by Santelmo · 1,575 words · 341 segments · language en · Watch on YouTube

Full transcript

  1. 0:05Hi.
  2. 0:07On this video, we'll be talking about
  3. 0:10the EIA/TIA wiring standards.
  4. 0:13So, EIA stands for Electronic Industries
  5. 0:16Alliance
  6. 0:18and TIA
  7. 0:20Telecommunications Industry Association.
  8. 0:24So, in
  9. 0:26systems administration, the system
  10. 0:28administrator has to ensure
  11. 0:31the standards or the standardization
  12. 0:35when it comes to
  13. 0:36the network infrastructure. And one way
  14. 0:38to ensure is
  15. 0:40the EIA/TIA wiring standards. This is
  16. 0:43the deployment
  17. 0:45and adaptation of the standards
  18. 0:48on the network infrastructure being
  19. 0:49managed by the systems admin.
  20. 0:57Okay, so for the outline of the topic
  21. 1:00so, we will be talking about the EIA/TIA
  22. 1:03wiring standards
  23. 1:05and the coverage area of the EIA/TIA,
  24. 1:09which includes entrance facility
  25. 1:12equipment room
  26. 1:14vertical cabling
  27. 1:16telecommunication closet or telecom
  28. 1:18closet
  29. 1:19you've got horizontal cabling
  30. 1:22and the work area. So, this comprises
  31. 1:25the EIA/TIA wiring standards for
  32. 1:28computer networks.
  33. 1:31Let's get started.
  34. 1:33Let's start with the EIA/TIA wiring
  35. 1:36standards
  36. 1:37description or definition.
  37. 1:39So, basically, this is the standards for
  38. 1:41commercial and telecommunications.
  39. 1:44It consists of a group of standard
  40. 1:48covering different aspects of a premise
  41. 1:51cabling and other wiring practices.
  42. 1:54So, if you will remember, you've got the
  43. 1:57color coding on the
  44. 2:01UTP, okay? So, that is basically based
  45. 2:04on the EIA/TIA wiring standards, wherein
  46. 2:07we have the EIA/TIA 568A and 568B color
  47. 2:12coding for UTP cables.
  48. 2:16Now, let's talk about the first
  49. 2:18area, which is the entrance facility.
  50. 2:21Now, entrance facility is an entrance to
  51. 2:24a building for both public network
  52. 2:26service cables, including wireless,
  53. 2:29including the entrance point of the
  54. 2:31building,
  55. 2:32and continuing to the entrance room or
  56. 2:35space.
  57. 2:37In every communication or or in every
  58. 2:40infrastructure network, so the
  59. 2:42horizontal cabling,
  60. 2:45the telecom outlets, the work area, the
  61. 2:48backbone,
  62. 2:49intermediate and main cross-connects,
  63. 2:53this should start on the
  64. 2:56entrance facility.
  65. 3:02Okay? So, entrance facility basically is
  66. 3:06a place
  67. 3:07in a campus or in a building wherein
  68. 3:10all the communications leading to the
  69. 3:13outside world
  70. 3:15is connected and
  71. 3:17uh organized and placed.
  72. 3:19So, if you have the internet or ISP
  73. 3:22connection, it should terminated
  74. 3:25or should be terminated on the entrance
  75. 3:26facility.
  76. 3:27If you have the cable TV, it should be
  77. 3:29terminated on the entrance facility.
  78. 3:31Basically, all your connections to the
  79. 3:34outside world is terminated on the
  80. 3:37entrance facility.
  81. 3:38Entrance facility is also
  82. 3:41an area where the responsibility of the
  83. 3:45network administrator or the systems
  84. 3:47administrator begins,
  85. 3:49and the responsibility of the service
  86. 3:52provider ends.
  87. 3:55So, in a given building, for instance,
  88. 3:58entrance facility is basically
  89. 4:01located on the entrance of the building,
  90. 4:05all right, or on the ground floor,
  91. 4:08wherein
  92. 4:09the network infrastructure being managed
  93. 4:12by the systems admin
  94. 4:14is
  95. 4:15or has started.
  96. 4:17Okay?
  97. 4:19So, on this diagram here, the entrance
  98. 4:21facility is
  99. 4:24the entrance of the office or the
  100. 4:26organization, which is on the ground
  101. 4:28floor.
  102. 4:32Okay. So, the next one is the equipment
  103. 4:34room.
  104. 4:35So, equipment room contains the main
  105. 4:37distribution frame, the main location
  106. 4:40for backbone cabling,
  107. 4:41phone systems, power protection, you've
  108. 4:44got a UPS, LAN equipment such as
  109. 4:47routers, switches, bridges, firewalls,
  110. 4:51hubs, and any file servers, or server
  111. 4:54farm,
  112. 4:55and data processing equipment, including
  113. 4:57the mechanical terminations.
  114. 5:00So, a typical equipment room look like
  115. 5:02this,
  116. 5:03wherein you have the server farm,
  117. 5:06all your core devices is located.
  118. 5:10If you still remember the hierarchy in
  119. 5:12network
  120. 5:13implementation,
  121. 5:15you've got the core, the distribution,
  122. 5:16and the access. Basically, access is on
  123. 5:20the user's end, distribution is on the
  124. 5:23telecom
  125. 5:24closets,
  126. 5:25and the core is basically
  127. 5:28inside the equipment room.
  128. 5:31Okay? So, on on the equipment room,
  129. 5:35or we call it the main distribution
  130. 5:36facility
  131. 5:38in some books, okay?
  132. 5:40So, observe that the cable is running on
  133. 5:44the ceiling, or
  134. 5:46it is on the or under that the
  135. 5:49between the floor
  136. 5:51and the base.
  137. 5:53All right? And as much as possible, all
  138. 5:55cables should be color-coded when you
  139. 5:58implement
  140. 5:59networking uh infrastructure.
  141. 6:02Okay?
  142. 6:04So, next is
  143. 6:06vertical cabling.
  144. 6:08Now, vertical cabling is also called as
  145. 6:10the backbone cabling or or backbone
  146. 6:12wiring.
  147. 6:14These are the wires that extend from the
  148. 6:17floor to floor across the campus
  149. 6:20or from telecommunication closets to an
  150. 6:22equipment room.
  151. 6:23So, this is contrasted with horizontal
  152. 6:27cabling,
  153. 6:28which connects individual workstation to
  154. 6:31the network.
  155. 6:33Now, based on our
  156. 6:36layout here, a vertical cabling
  157. 6:39basically connects your
  158. 6:41telecommunication closet
  159. 6:43or telecom closet or TC.
  160. 6:46So, it is recommended in this design
  161. 6:49for every floor of the building,
  162. 6:51there should be a telecommunication
  163. 6:53closet.
  164. 6:56And this telecommunication closet on
  165. 6:58each floor is connected via vertical
  166. 7:01cabling or backbone cabling.
  167. 7:05So, as what I've said earlier,
  168. 7:06the telecommunication closet serves as
  169. 7:09the distribution
  170. 7:11on the infrastructure.
  171. 7:14And the equipment room serves as the
  172. 7:16core
  173. 7:18of the infrastructure.
  174. 7:23Okay? So, the next area is telecom
  175. 7:26closet or telecommunication closet.
  176. 7:28So, this is also known as the wiring
  177. 7:31closet,
  178. 7:32okay?
  179. 7:33Or the distribution facility,
  180. 7:36okay? Or in some books, they refer to as
  181. 7:39the intermediate distribution facility.
  182. 7:42So, a room or closet that houses all the
  183. 7:44telecommunication equipment, especially
  184. 7:46the switches, that that distributes
  185. 7:49um the network over the infrastructure.
  186. 7:55Servers as termination point for the
  187. 7:59horizontal cabling system
  188. 8:01of a network. And it contains the
  189. 8:04network distribution panels,
  190. 8:06cross-connects, and backbone.
  191. 8:09So, again, in our building layout,
  192. 8:12telecommunication closet
  193. 8:15is this orange box here,
  194. 8:17which distributes access to all the
  195. 8:19workstations and work area over the
  196. 8:22infrastructure.
  197. 8:24Okay? Now, if we get inside the
  198. 8:27telecommunication closet, basically it
  199. 8:29contains switches, okay, which is used
  200. 8:32for
  201. 8:33distribution.
  202. 8:36Now, in some organization, this is how a
  203. 8:39typical telecom closet look like.
  204. 8:41Okay? You've got the messy connections,
  205. 8:44all right?
  206. 8:46So, and if you will observe on this
  207. 8:48diagram,
  208. 8:49so the cable is not organized,
  209. 8:52and they are using a single-colored
  210. 8:56UTP cable.
  211. 8:58Okay? A good design of a
  212. 9:00telecommunication closet should be look
  213. 9:01like this.
  214. 9:03Wherein your cables are organized,
  215. 9:05you're using a color-coded cables. For
  216. 9:08instance, all blue goes to this area,
  217. 9:11all yellow goes to this area, all green
  218. 9:13goes to this floor, and so on.
  219. 9:15Okay? It should be organized.
  220. 9:18So, that's telecommunication closet or
  221. 9:20[music]
  222. 9:21the
  223. 9:23intermediate distribution facility or
  224. 9:25IDF.
  225. 9:30Okay, next would be the horizontal
  226. 9:32cabling.
  227. 9:34Horizontal cabling is any cabling that
  228. 9:36is used to connect floors wiring closet
  229. 9:39to wall plates in the work area
  230. 9:42to provide local area network drops for
  231. 9:44connecting users computers to the
  232. 9:46network.
  233. 9:48So this includes horizontal cables,
  234. 9:51telecommunications outlet or connectors
  235. 9:54in the work area.
  236. 9:56You've got your wall patch
  237. 9:58um connections
  238. 10:00or wall outlet, mechanical terminations
  239. 10:03and patch cords or jumpers located in
  240. 10:07the telecommunications room
  241. 10:08>> [music]
  242. 10:09>> and may include multi-user
  243. 10:10telecommunications outlet assemblies and
  244. 10:13consolidation points.
  245. 10:16So using again our layout here or the
  246. 10:19building layout,
  247. 10:20so the horizontal cabling is the cable
  248. 10:23that runs from the telecom closet
  249. 10:26going to the wall plates on the work
  250. 10:27area.
  251. 10:29So this red wires here is considered to
  252. 10:31be a horizontal cable or horizontal
  253. 10:33cabling.
  254. 10:35This uses
  255. 10:36UTP
  256. 10:38to run from the telecom closet to the
  257. 10:40wall plates on the work area and this
  258. 10:42has a maximum distance of or maximum
  259. 10:45length
  260. 10:46of 90 m.
  261. 10:49Well, in theory,
  262. 10:50UTP cables can be run up to one one
  263. 10:55100 m.
  264. 10:57Okay?
  265. 10:58So and therefore
  266. 11:00the practice on the EIA/TIA wiring
  267. 11:03standard is to use only a maximum length
  268. 11:05of 90 m on the horizontal cable.
  269. 11:08Okay?
  270. 11:09So from the horizontal cable, basically,
  271. 11:12it is terminated on the wall plates.
  272. 11:15Okay?
  273. 11:16And from the wall plates going to the
  274. 11:18work station, in there on the work area,
  275. 11:21we uses a patch cable and patch cable
  276. 11:24recommended length is 6 m.
  277. 11:27So you've got horizontal cabling
  278. 11:30having a 90 m maximum length and patch
  279. 11:33cable with a 6 m maximum length. So,
  280. 11:35that's 96.
  281. 11:38Okay, 96 m in total. Now, where is the 4
  282. 11:41m? Okay? So, 4 m is basically used
  283. 11:46on the
  284. 11:49telecommunication closet, wherein we
  285. 11:52connect patch panel and the switch.
  286. 11:55Okay? The cable that is used to connect
  287. 11:58patch panel to the switch
  288. 12:00should be having a maximum length of 4
  289. 12:02m.
  290. 12:03So, all in all, the total run of the UTP
  291. 12:06cable is 100 m.
  292. 12:10Okay?
  293. 12:15All right. So, the last one would be the
  294. 12:17work area. Basically, the work area is
  295. 12:19where the workstation is located.
  296. 12:22This is where the end users in the
  297. 12:25production area
  298. 12:26is located. So, the work area is the
  299. 12:29space inside a building where employees,
  300. 12:33building occupants, or system users
  301. 12:35work, and their communication equipment.
  302. 12:39This is also the area where the
  303. 12:40horizontal communication cables are
  304. 12:42terminated.
  305. 12:44Okay? Now, on this example,
  306. 12:48basically, this is the work area.
  307. 12:50Okay? This is where your workers,
  308. 12:55your programmers, are working. Okay? And
  309. 12:58this is where also the horizontal cable
  310. 13:00is terminated via the wall plates.
  311. 13:04Okay?
  312. 13:05So, this are the components of the
  313. 13:08EIA/TIA wiring standard. So, if a
  314. 13:10systems administrator is going to
  315. 13:12implement a wiring
  316. 13:14infrastructure, okay, so for the
  317. 13:16organization,
  318. 13:18they have to ensure that these
  319. 13:19components
  320. 13:21are present on the implementation.
  321. 13:24Okay? So, to summarize, again, the
  322. 13:27EIA/TIA wiring standard has the
  323. 13:29following area. Namely, entrance
  324. 13:32facility,
  325. 13:34equipment room,
  326. 13:36telecommunication closets,
  327. 13:38which are connected by a backbone
  328. 13:41cabling or vertical cabling.
  329. 13:43You've got horizontal cabling, which
  330. 13:45runs from the telecom closet to the work
  331. 13:47area, and terminated on the wall plates.
  332. 13:50And the last one is the work area.
  333. 13:53Okay? So,
  334. 13:56those are the components that needs to
  335. 13:58be ensured
  336. 14:01in adopting these standards in
  337. 14:02structured cabling for computer
  338. 14:04networks.
  339. 14:06All right? So, that ends up my
  340. 14:08presentation.
  341. 14:11Thank you so much for listening.

About this transcript

This page contains the full transcript of EIA TIA Wiring Standards by Santelmo, generated from the public captions YouTube serves with the video. The transcript has 1,575 words across 341 segments, with the original timestamps preserved so you can click any line to jump to that moment in the embedded player.

What you can do with it

Use the transcript to take notes, quote the speaker, build a study guide, generate a summary with ChatGPT or Claude via the YouTube Summary tool, or export it as a timed subtitle file with YouTube to SRT. You can also re-open it in the transcriber to translate the transcript into 100+ languages.

Free YouTube transcript tool

YouTube2Text is a free YouTube transcript generator — no signup, no daily limit. Paste any YouTube link and get the full transcript instantly, with timestamps, click-to-jump, translation to 100+ languages, AI prompts for ChatGPT, Claude, and Gemini, and exports to TXT, SRT, VTT, or Markdown.