  1. 0:00hi and welcome to this presentation on a
  2. 0:02crp
  3. 0:03circuit best practice application my
  4. 0:06name
  5. 0:07is ryan orbell the national segment
  6. 0:09manager at burkitt for the hygienic
  7. 0:11industry
  8. 0:12at burkitt hygienic covers the food
  9. 0:15beverage dairy and pharmaceutical
  10. 0:18industries
  11. 0:19hygienic is one of the four segments
  12. 0:21covered by burkitt with the others being
  13. 0:23water
  14. 0:24gas and the microfluidic industries
  15. 0:28today i would like to share with you a
  16. 0:30very short introduction
  17. 0:32this should only take us no more than 15
  18. 0:34minutes to present to you
  19. 0:36a successful best practice cip
  20. 0:38application
  21. 0:39of course this is not a one size fits
  22. 0:42all as every product
  23. 0:44and application can differ some
  24. 0:47additional cycles
  25. 0:48or steps may be required to those shown
  26. 0:50today
  27. 0:51however this is a very good basis and i
  28. 0:54will share with you some good insights
  29. 0:56to helping you
  30. 0:57to achieve a good and an efficient crp
  31. 1:01process a cip
  32. 1:04system is best explained by the
  33. 1:06following it is the cleaning of the
  34. 1:08complete items of
  35. 1:10plant or pipeline circuits without
  36. 1:13dismantling or opening of the equipment
  37. 1:16and with little or no manual involvement
  38. 1:18on the part of the operator
  39. 1:21the process involves the jetting or
  40. 1:24spraying of surfaces
  41. 1:26or circulation of cleaning solutions
  42. 1:28through the plant
  43. 1:29under conditions of increased turbulence
  44. 1:33flow velocity time and temperature
  45. 1:37generally the parts of the process to be
  46. 1:40cleaned will include
  47. 1:41everything that comes into contact with
  48. 1:43the product
  49. 1:44such as tanks valves pumps
  50. 1:48and fittings of course
  51. 1:51today most modern food and beverage
  52. 1:54businesses
  53. 1:55have adopted process automation in one
  54. 1:57format or another
  55. 1:59however the technology available today
  56. 2:02has continually evolved
  57. 2:04quite considerably over the past few
  58. 2:06years
  59. 2:07leading to improvements in design
  60. 2:10efficiency
  61. 2:11and reliability with this new technology
  62. 2:14we now offer our customers more
  63. 2:16ownership and
  64. 2:17information regarding management of your
  65. 2:20assets
  66. 2:21with the evolvement of industry 4.0
  67. 2:25there are now many automation methods
  68. 2:27that can be adopted
  69. 2:29to increase the gathering of additional
  70. 2:31data which directly supports schedule
  71. 2:34maintenance intervals
  72. 2:35rather than interruptions in the
  73. 2:38day-to-day running of your operations
  74. 2:41so what is a cip system there are three
  75. 2:44stages
  76. 2:45in the first step we use mechanical
  77. 2:47force
  78. 2:49here we use the water to remove the
  79. 2:51buildup of residues through
  80. 2:52impacts and turbulences
  81. 2:56in the chemical step we use suitable
  82. 2:59chemicals to break up
  83. 3:01and remove any remaining residues
  84. 3:03through chemical actions
  85. 3:06and then we have the sterilization and
  86. 3:08the sanitation step
  87. 3:10this kills any remaining microorganisms
  88. 3:14and the biofilm to an acceptable level
  89. 3:17the water is used for the initial flush
  90. 3:20and clean of the system
  91. 3:21creating impacts under pressure and
  92. 3:24turbulences through the correct flow
  93. 3:26profiles
  94. 3:28under conditions of turbulent flow
  95. 3:31if sugar is present you will start with
  96. 3:33a hot water flush to help dissolve the
  97. 3:36sugars
  98. 3:37with the alkali most of the food
  99. 3:40products
  100. 3:41including milk and dairy will contain
  101. 3:43proteins and fats
  102. 3:45therefore an alkali detergent is
  103. 3:47required to help break this down
  104. 3:50and then we have the acid if the product
  105. 3:53contains salts and minerals
  106. 3:55then a suitably qualified strength of
  107. 3:58acid is required
  108. 4:00the acid helps to remove any scale
  109. 4:02buildup in the pipes
  110. 4:04but not every crp application will
  111. 4:07require an
  112. 4:08acid rinse every time and the frequency
  113. 4:11will be determined by the product
  114. 4:13and application many applications may
  115. 4:17only demand an asset cycle once every
  116. 4:19several weeks
  117. 4:21or maybe not even at all an
  118. 4:24efficient cleaning recipe is based on
  119. 4:26four key parameters
  120. 4:28time the time the flush the rinse water
  121. 4:32or the chemical is in contact with the
  122. 4:34process to be cleaned
  123. 4:36we have the temperature of the cleaning
  124. 4:37products this is typically set to
  125. 4:40anywhere between
  126. 4:4150 to 75 degrees celsius to break down
  127. 4:45the fats
  128. 4:46the proteins the salts and the minerals
  129. 4:50then we have the mechanics this is the
  130. 4:53turbulent flow velocity required
  131. 4:55and the pressure to clean the soil from
  132. 4:57the surfaces
  133. 4:59and we have the cleaning agents and
  134. 5:01chemicals which must be a suitable
  135. 5:03concentration strength
  136. 5:04to obtain a clean process but we also
  137. 5:08must ensure
  138. 5:10that strong design principles are
  139. 5:12implemented
  140. 5:13remember you can't clean what you can't
  141. 5:16contact so there should be no dead leg
  142. 5:18zones or undrainable pockets
  143. 5:20that you can't access and of course the
  144. 5:23clean and place cycle must be separated
  145. 5:26from the process cycle
  146. 5:27to prevent any cross-product
  147. 5:30contamination
  148. 5:31so now we are going to dig a bit deeper
  149. 5:34into understanding the principle of each
  150. 5:36of the cip sequences
  151. 5:39the pre-rinse is the first step
  152. 5:42the pre-rinse cycles through the heat
  153. 5:44exchanger
  154. 5:45this brings the cleaning agents up to
  155. 5:47temperature
  156. 5:48and goes out the cip supply to the
  157. 5:50equipment
  158. 5:51and cycles back via the cip return and
  159. 5:54down to drain
  160. 5:56the pre-rinse cycle is responsible to
  161. 5:59physically clean the equipment
  162. 6:01to remove all of the visible dirt from
  163. 6:03the surface under conditions of
  164. 6:05turbulent flow
  165. 6:07the correct fluid velocity must be
  166. 6:09achieved to obtain good cleaning
  167. 6:12this turbulent flow is achieved between
  168. 6:141.5
  169. 6:15to 2.1 meters a second and generally the
  170. 6:19pre-rent cycle is set at a time by the
  171. 6:21commissioning engineer
  172. 6:23until the cip return water is running
  173. 6:25clear
  174. 6:28in the pre-rinse step it is very
  175. 6:31important to achieve the correct
  176. 6:32flow velocity to achieve good cleaning
  177. 6:35laminar flow
  178. 6:36does not provide good cleaning
  179. 6:38characteristics due to the flow profile
  180. 6:41therefore turbulent flow is the
  181. 6:43objective
  182. 6:44to achieve a better flow profile and
  183. 6:47therefore to achieve a much better clean
  184. 6:52in the second step the cleaning agents
  185. 6:54the chemicals are introduced
  186. 6:57a caustic solution is used to break down
  187. 6:59the fats and the proteins
  188. 7:01these cleaning agents will be addressing
  189. 7:04the areas that could be detected by
  190. 7:06taste or smell but are not visible to
  191. 7:09the naked eye
  192. 7:11the caustic solution is circulated
  193. 7:13through to the plant equipment to be
  194. 7:15cleaned
  195. 7:16via the cip supply and returns via the
  196. 7:20cip return
  197. 7:22the sensors in line will monitor the
  198. 7:24temperature to ensure the media
  199. 7:26is at the correct temperature flow
  200. 7:29to confirm the correct flow velocity is
  201. 7:31achieved and a conductivity sensor
  202. 7:33to determine the product differentiation
  203. 7:36between the water
  204. 7:37and the cost so the cost by the
  205. 7:40concentration level can be returned to
  206. 7:42the caustic tank
  207. 7:44the remaining caustic is then chased
  208. 7:46from the system by the fresh water tank
  209. 7:49or the rinse recovery tank and the
  210. 7:51conductivity sensor detects the return
  211. 7:54of caustic to tank
  212. 7:55and when the water is detected the water
  213. 7:57is either returned to a rinse recovery
  214. 8:00tank
  215. 8:00or down to drain and the third step
  216. 8:04the cleaning agents the acid is
  217. 8:06introduced
  218. 8:07in this step the acid base is used to
  219. 8:09remove the salts
  220. 8:11and the minerals the acid solution is
  221. 8:14circulated through to the plant
  222. 8:16equipment to be cleaned
  223. 8:18this goes out via the cip supply and
  224. 8:20returns via the cip return
  225. 8:23the sensors in line will monitor the
  226. 8:25temperature to ensure the media is at
  227. 8:28the correct temperature
  228. 8:29the flow to confirm the correct flow
  229. 8:32velocity is achieved
  230. 8:33and a conductivity sensor to determine
  231. 8:36when the acid by the concentration level
  232. 8:38is returned to the acid tank
  233. 8:41the remaining acid is then chased from
  234. 8:43the system by the fresh water tank or
  235. 8:45rinse recovery tank
  236. 8:47and the conductivity sensor again
  237. 8:49detects the return of acid to tank
  238. 8:52and when the water is detected the water
  239. 8:54is either returned to the rinse recovery
  240. 8:56tank
  241. 8:56or down to drain some crp applications
  242. 9:00may only require an acid rinse once
  243. 9:03every several weeks
  244. 9:05this is designed to reduce the scale
  245. 9:06build up on the pipes
  246. 9:08hence why every application can differ
  247. 9:10and it is not a one size fits all
  248. 9:13some applications such as juice may not
  249. 9:16even use an
  250. 9:17acid wash at all and then
  251. 9:20we have the cleaning agents where we
  252. 9:22need to disinfect
  253. 9:24the object here is to introduce a
  254. 9:26suitable disinfectant to destroy
  255. 9:29or inactivate any serious fungi or
  256. 9:32bacterias
  257. 9:33here we can recover to the rinse
  258. 9:35recovery tank for the first flush
  259. 9:37in the next crp sequence the flush water
  260. 9:40is designed to remove or chase the
  261. 9:43cleaning reagent from the production
  262. 9:45system
  263. 9:46it usually contains some residual
  264. 9:48cleaning reagent
  265. 9:50and can be captured and reused provided
  266. 9:52that it is of a quality that is fit for
  267. 9:54purpose
  268. 9:55for the intended use the rinse recovery
  269. 9:58tank is a different tank to the mains
  270. 10:00water tank
  271. 10:01therefore the rinse recovery is used for
  272. 10:04the first rinse
  273. 10:05of the next crp cycle so how can we help
  274. 10:09anywhere where process control is
  275. 10:11required such as the on off
  276. 10:13process valves in the cip circuit to
  277. 10:16control the flow paths for the product
  278. 10:18and cleaning media
  279. 10:20the modulating control valves
  280. 10:22interfacing with the heat exchangers
  281. 10:24to ensure correct media temperature is
  282. 10:27achieved
  283. 10:28the flow and temperature sensors to
  284. 10:30ensure correct flow velocities
  285. 10:32on both the cip supply and crp
  286. 10:35return lines in fact these flow meters
  287. 10:39sorry in fact these flow meters can also
  288. 10:42detect the change in media
  289. 10:44and the process line to determine when
  290. 10:46to return the chemicals
  291. 10:48to the tank or the water to the drain
  292. 10:51plus conductivity sensors to monitor the
  293. 10:54process
  294. 10:54to validate the concentration and
  295. 10:57cleaning target levels are met
  296. 10:59as well as smart transmitters and
  297. 11:01controllers
  298. 11:02typically burkitt can help you anywhere
  299. 11:05that makes your process
  300. 11:07more efficient most cip sequences
  301. 11:11are never altered following installation
  302. 11:14they are usually set to defaults which
  303. 11:16are set during commissioning
  304. 11:18however cip operators can optimize their
  305. 11:21systems by monitoring the number
  306. 11:23of key parameters continually these are
  307. 11:27what temperature and concentration or
  308. 11:30conductivity are the caustic tanks set
  309. 11:32to
  310. 11:33often they will be set too high with no
  311. 11:35added benefit
  312. 11:37consider the pre-rinse does it run clear
  313. 11:39and then keep going
  314. 11:42is the pre-rinse eliminating sufficient
  315. 11:44residue
  316. 11:45could it operate more efficiently the
  317. 11:48caustic fill how high are the return
  318. 11:50conductivity and temperature
  319. 11:51transmitters set
  320. 11:53keeping parameters as near as possible
  321. 11:56to the effect of temperature
  322. 11:58and conductivity leads to more efficient
  323. 12:00processes
  324. 12:01rather than delivering no added benefit
  325. 12:04but more cost and resource inputs
  326. 12:07water is often your most valuable asset
  327. 12:10so a constant monitoring system
  328. 12:12to reduce the unnecessary consumption of
  329. 12:15water
  330. 12:15and for that matter heat can go a long
  331. 12:18way to optimizing your crp
  332. 12:20costs you really want to avoid any
  333. 12:23wasted resources wherever possible
  334. 12:26so as you've seen it is necessary during
  335. 12:29planning of your production processes
  336. 12:31to consider a suitable clean and place
  337. 12:33installation
  338. 12:34that meets your hygiene requirements
  339. 12:38with a number of strategically located
  340. 12:40system houses spread out across the
  341. 12:42globe
  342. 12:43burkett extends our offering from a
  343. 12:45product supplier
  344. 12:47to extensive engineering and consulting
  345. 12:50where we can design build
  346. 12:52and deliver complete system solutions
  347. 12:56so with extensive cross-segment
  348. 12:57experience and a broad product portfolio
  349. 13:00consisting of controllers and
  350. 13:02transmitters
  351. 13:04sensors process valves
  352. 13:07analytical monitoring systems and
  353. 13:10numerous other intelligent automation
  354. 13:12concepts to control compatible
  355. 13:14components
  356. 13:15burkitt can ensure a robust clean
  357. 13:19and efficient solution in virtually any
  358. 13:22application
  359. 13:23so today we have proven to you that we
  360. 13:27have
  361. 13:28field hardware competence we offer
  362. 13:30leading technology and process
  363. 13:32automation
  364. 13:34we meet all network demands and we offer
  365. 13:38support from local
  366. 13:40and international teams well that
  367. 13:42concludes today's
  368. 13:44short introduction to a successful crp
  369. 13:46application of course
  370. 13:48as i said earlier this is not a one size
  371. 13:51fits all
  372. 13:52as every product and application can
  373. 13:54differ
  374. 13:55if you would like to discuss your
  375. 13:57application further and how we can help
  376. 14:00then please reach out to me i'm looking
  377. 14:02forward to hearing from you
  378. 14:03thank you for your time today

About this transcript

This page contains the full transcript of Clean in Place (CIP) Best Practice by Burkert Australia, generated from the public captions YouTube serves with the video. The transcript has 1,917 words across 378 segments, with the original timestamps preserved so you can click any line to jump to that moment in the embedded player.

What you can do with it

Use the transcript to take notes, quote the speaker, build a study guide, generate a summary with ChatGPT or Claude via the YouTube Summary tool, or export it as a timed subtitle file with YouTube to SRT. You can also re-open it in the transcriber to choose a caption track available on the video.

Free YouTube transcript tool

YouTube2Text is a free YouTube transcript generator — no signup, no daily limit. Paste any YouTube link and get the full transcript instantly, with timestamps, click-to-jump, caption language selection, AI prompts for ChatGPT, Claude, and Gemini, and exports to TXT, SRT, VTT, or Markdown.