- 0:00hi and welcome to this presentation on a
- 0:02crp
- 0:03circuit best practice application my
- 0:06name
- 0:07is ryan orbell the national segment
- 0:09manager at burkitt for the hygienic
- 0:11industry
- 0:12at burkitt hygienic covers the food
- 0:15beverage dairy and pharmaceutical
- 0:18industries
- 0:19hygienic is one of the four segments
- 0:21covered by burkitt with the others being
- 0:23water
- 0:24gas and the microfluidic industries
- 0:28today i would like to share with you a
- 0:30very short introduction
- 0:32this should only take us no more than 15
- 0:34minutes to present to you
- 0:36a successful best practice cip
- 0:38application
- 0:39of course this is not a one size fits
- 0:42all as every product
- 0:44and application can differ some
- 0:47additional cycles
- 0:48or steps may be required to those shown
- 0:50today
- 0:51however this is a very good basis and i
- 0:54will share with you some good insights
- 0:56to helping you
- 0:57to achieve a good and an efficient crp
- 1:01process a cip
- 1:04system is best explained by the
- 1:06following it is the cleaning of the
- 1:08complete items of
- 1:10plant or pipeline circuits without
- 1:13dismantling or opening of the equipment
- 1:16and with little or no manual involvement
- 1:18on the part of the operator
- 1:21the process involves the jetting or
- 1:24spraying of surfaces
- 1:26or circulation of cleaning solutions
- 1:28through the plant
- 1:29under conditions of increased turbulence
- 1:33flow velocity time and temperature
- 1:37generally the parts of the process to be
- 1:40cleaned will include
- 1:41everything that comes into contact with
- 1:43the product
- 1:44such as tanks valves pumps
- 1:48and fittings of course
- 1:51today most modern food and beverage
- 1:54businesses
- 1:55have adopted process automation in one
- 1:57format or another
- 1:59however the technology available today
- 2:02has continually evolved
- 2:04quite considerably over the past few
- 2:06years
- 2:07leading to improvements in design
- 2:10efficiency
- 2:11and reliability with this new technology
- 2:14we now offer our customers more
- 2:16ownership and
- 2:17information regarding management of your
- 2:20assets
- 2:21with the evolvement of industry 4.0
- 2:25there are now many automation methods
- 2:27that can be adopted
- 2:29to increase the gathering of additional
- 2:31data which directly supports schedule
- 2:34maintenance intervals
- 2:35rather than interruptions in the
- 2:38day-to-day running of your operations
- 2:41so what is a cip system there are three
- 2:44stages
- 2:45in the first step we use mechanical
- 2:47force
- 2:49here we use the water to remove the
- 2:51buildup of residues through
- 2:52impacts and turbulences
- 2:56in the chemical step we use suitable
- 2:59chemicals to break up
- 3:01and remove any remaining residues
- 3:03through chemical actions
- 3:06and then we have the sterilization and
- 3:08the sanitation step
- 3:10this kills any remaining microorganisms
- 3:14and the biofilm to an acceptable level
- 3:17the water is used for the initial flush
- 3:20and clean of the system
- 3:21creating impacts under pressure and
- 3:24turbulences through the correct flow
- 3:26profiles
- 3:28under conditions of turbulent flow
- 3:31if sugar is present you will start with
- 3:33a hot water flush to help dissolve the
- 3:36sugars
- 3:37with the alkali most of the food
- 3:40products
- 3:41including milk and dairy will contain
- 3:43proteins and fats
- 3:45therefore an alkali detergent is
- 3:47required to help break this down
- 3:50and then we have the acid if the product
- 3:53contains salts and minerals
- 3:55then a suitably qualified strength of
- 3:58acid is required
- 4:00the acid helps to remove any scale
- 4:02buildup in the pipes
- 4:04but not every crp application will
- 4:07require an
- 4:08acid rinse every time and the frequency
- 4:11will be determined by the product
- 4:13and application many applications may
- 4:17only demand an asset cycle once every
- 4:19several weeks
- 4:21or maybe not even at all an
- 4:24efficient cleaning recipe is based on
- 4:26four key parameters
- 4:28time the time the flush the rinse water
- 4:32or the chemical is in contact with the
- 4:34process to be cleaned
- 4:36we have the temperature of the cleaning
- 4:37products this is typically set to
- 4:40anywhere between
- 4:4150 to 75 degrees celsius to break down
- 4:45the fats
- 4:46the proteins the salts and the minerals
- 4:50then we have the mechanics this is the
- 4:53turbulent flow velocity required
- 4:55and the pressure to clean the soil from
- 4:57the surfaces
- 4:59and we have the cleaning agents and
- 5:01chemicals which must be a suitable
- 5:03concentration strength
- 5:04to obtain a clean process but we also
- 5:08must ensure
- 5:10that strong design principles are
- 5:12implemented
- 5:13remember you can't clean what you can't
- 5:16contact so there should be no dead leg
- 5:18zones or undrainable pockets
- 5:20that you can't access and of course the
- 5:23clean and place cycle must be separated
- 5:26from the process cycle
- 5:27to prevent any cross-product
- 5:30contamination
- 5:31so now we are going to dig a bit deeper
- 5:34into understanding the principle of each
- 5:36of the cip sequences
- 5:39the pre-rinse is the first step
- 5:42the pre-rinse cycles through the heat
- 5:44exchanger
- 5:45this brings the cleaning agents up to
- 5:47temperature
- 5:48and goes out the cip supply to the
- 5:50equipment
- 5:51and cycles back via the cip return and
- 5:54down to drain
- 5:56the pre-rinse cycle is responsible to
- 5:59physically clean the equipment
- 6:01to remove all of the visible dirt from
- 6:03the surface under conditions of
- 6:05turbulent flow
- 6:07the correct fluid velocity must be
- 6:09achieved to obtain good cleaning
- 6:12this turbulent flow is achieved between
- 6:141.5
- 6:15to 2.1 meters a second and generally the
- 6:19pre-rent cycle is set at a time by the
- 6:21commissioning engineer
- 6:23until the cip return water is running
- 6:25clear
- 6:28in the pre-rinse step it is very
- 6:31important to achieve the correct
- 6:32flow velocity to achieve good cleaning
- 6:35laminar flow
- 6:36does not provide good cleaning
- 6:38characteristics due to the flow profile
- 6:41therefore turbulent flow is the
- 6:43objective
- 6:44to achieve a better flow profile and
- 6:47therefore to achieve a much better clean
- 6:52in the second step the cleaning agents
- 6:54the chemicals are introduced
- 6:57a caustic solution is used to break down
- 6:59the fats and the proteins
- 7:01these cleaning agents will be addressing
- 7:04the areas that could be detected by
- 7:06taste or smell but are not visible to
- 7:09the naked eye
- 7:11the caustic solution is circulated
- 7:13through to the plant equipment to be
- 7:15cleaned
- 7:16via the cip supply and returns via the
- 7:20cip return
- 7:22the sensors in line will monitor the
- 7:24temperature to ensure the media
- 7:26is at the correct temperature flow
- 7:29to confirm the correct flow velocity is
- 7:31achieved and a conductivity sensor
- 7:33to determine the product differentiation
- 7:36between the water
- 7:37and the cost so the cost by the
- 7:40concentration level can be returned to
- 7:42the caustic tank
- 7:44the remaining caustic is then chased
- 7:46from the system by the fresh water tank
- 7:49or the rinse recovery tank and the
- 7:51conductivity sensor detects the return
- 7:54of caustic to tank
- 7:55and when the water is detected the water
- 7:57is either returned to a rinse recovery
- 8:00tank
- 8:00or down to drain and the third step
- 8:04the cleaning agents the acid is
- 8:06introduced
- 8:07in this step the acid base is used to
- 8:09remove the salts
- 8:11and the minerals the acid solution is
- 8:14circulated through to the plant
- 8:16equipment to be cleaned
- 8:18this goes out via the cip supply and
- 8:20returns via the cip return
- 8:23the sensors in line will monitor the
- 8:25temperature to ensure the media is at
- 8:28the correct temperature
- 8:29the flow to confirm the correct flow
- 8:32velocity is achieved
- 8:33and a conductivity sensor to determine
- 8:36when the acid by the concentration level
- 8:38is returned to the acid tank
- 8:41the remaining acid is then chased from
- 8:43the system by the fresh water tank or
- 8:45rinse recovery tank
- 8:47and the conductivity sensor again
- 8:49detects the return of acid to tank
- 8:52and when the water is detected the water
- 8:54is either returned to the rinse recovery
- 8:56tank
- 8:56or down to drain some crp applications
- 9:00may only require an acid rinse once
- 9:03every several weeks
- 9:05this is designed to reduce the scale
- 9:06build up on the pipes
- 9:08hence why every application can differ
- 9:10and it is not a one size fits all
- 9:13some applications such as juice may not
- 9:16even use an
- 9:17acid wash at all and then
- 9:20we have the cleaning agents where we
- 9:22need to disinfect
- 9:24the object here is to introduce a
- 9:26suitable disinfectant to destroy
- 9:29or inactivate any serious fungi or
- 9:32bacterias
- 9:33here we can recover to the rinse
- 9:35recovery tank for the first flush
- 9:37in the next crp sequence the flush water
- 9:40is designed to remove or chase the
- 9:43cleaning reagent from the production
- 9:45system
- 9:46it usually contains some residual
- 9:48cleaning reagent
- 9:50and can be captured and reused provided
- 9:52that it is of a quality that is fit for
- 9:54purpose
- 9:55for the intended use the rinse recovery
- 9:58tank is a different tank to the mains
- 10:00water tank
- 10:01therefore the rinse recovery is used for
- 10:04the first rinse
- 10:05of the next crp cycle so how can we help
- 10:09anywhere where process control is
- 10:11required such as the on off
- 10:13process valves in the cip circuit to
- 10:16control the flow paths for the product
- 10:18and cleaning media
- 10:20the modulating control valves
- 10:22interfacing with the heat exchangers
- 10:24to ensure correct media temperature is
- 10:27achieved
- 10:28the flow and temperature sensors to
- 10:30ensure correct flow velocities
- 10:32on both the cip supply and crp
- 10:35return lines in fact these flow meters
- 10:39sorry in fact these flow meters can also
- 10:42detect the change in media
- 10:44and the process line to determine when
- 10:46to return the chemicals
- 10:48to the tank or the water to the drain
- 10:51plus conductivity sensors to monitor the
- 10:54process
- 10:54to validate the concentration and
- 10:57cleaning target levels are met
- 10:59as well as smart transmitters and
- 11:01controllers
- 11:02typically burkitt can help you anywhere
- 11:05that makes your process
- 11:07more efficient most cip sequences
- 11:11are never altered following installation
- 11:14they are usually set to defaults which
- 11:16are set during commissioning
- 11:18however cip operators can optimize their
- 11:21systems by monitoring the number
- 11:23of key parameters continually these are
- 11:27what temperature and concentration or
- 11:30conductivity are the caustic tanks set
- 11:32to
- 11:33often they will be set too high with no
- 11:35added benefit
- 11:37consider the pre-rinse does it run clear
- 11:39and then keep going
- 11:42is the pre-rinse eliminating sufficient
- 11:44residue
- 11:45could it operate more efficiently the
- 11:48caustic fill how high are the return
- 11:50conductivity and temperature
- 11:51transmitters set
- 11:53keeping parameters as near as possible
- 11:56to the effect of temperature
- 11:58and conductivity leads to more efficient
- 12:00processes
- 12:01rather than delivering no added benefit
- 12:04but more cost and resource inputs
- 12:07water is often your most valuable asset
- 12:10so a constant monitoring system
- 12:12to reduce the unnecessary consumption of
- 12:15water
- 12:15and for that matter heat can go a long
- 12:18way to optimizing your crp
- 12:20costs you really want to avoid any
- 12:23wasted resources wherever possible
- 12:26so as you've seen it is necessary during
- 12:29planning of your production processes
- 12:31to consider a suitable clean and place
- 12:33installation
- 12:34that meets your hygiene requirements
- 12:38with a number of strategically located
- 12:40system houses spread out across the
- 12:42globe
- 12:43burkett extends our offering from a
- 12:45product supplier
- 12:47to extensive engineering and consulting
- 12:50where we can design build
- 12:52and deliver complete system solutions
- 12:56so with extensive cross-segment
- 12:57experience and a broad product portfolio
- 13:00consisting of controllers and
- 13:02transmitters
- 13:04sensors process valves
- 13:07analytical monitoring systems and
- 13:10numerous other intelligent automation
- 13:12concepts to control compatible
- 13:14components
- 13:15burkitt can ensure a robust clean
- 13:19and efficient solution in virtually any
- 13:22application
- 13:23so today we have proven to you that we
- 13:27have
- 13:28field hardware competence we offer
- 13:30leading technology and process
- 13:32automation
- 13:34we meet all network demands and we offer
- 13:38support from local
- 13:40and international teams well that
- 13:42concludes today's
- 13:44short introduction to a successful crp
- 13:46application of course
- 13:48as i said earlier this is not a one size
- 13:51fits all
- 13:52as every product and application can
- 13:54differ
- 13:55if you would like to discuss your
- 13:57application further and how we can help
- 14:00then please reach out to me i'm looking
- 14:02forward to hearing from you
- 14:03thank you for your time today
About this transcript
This page contains the full transcript of Clean in Place (CIP) Best Practice by Burkert Australia, generated from the public captions YouTube serves with the video. The transcript has 1,917 words across 378 segments, with the original timestamps preserved so you can click any line to jump to that moment in the embedded player.
What you can do with it
Use the transcript to take notes, quote the speaker, build a study guide, generate a summary with ChatGPT or Claude via the YouTube Summary tool, or export it as a timed subtitle file with YouTube to SRT. You can also re-open it in the transcriber to choose a caption track available on the video.
Free YouTube transcript tool
YouTube2Text is a free YouTube transcript generator — no signup, no daily limit. Paste any YouTube link and get the full transcript instantly, with timestamps, click-to-jump, caption language selection, AI prompts for ChatGPT, Claude, and Gemini, and exports to TXT, SRT, VTT, or Markdown.