  1. 0:01hello and welcome to the fourth video of
  2. 0:03the basic training program
  3. 0:05in this video we will talk about basic
  4. 0:08therapy we will learn about what basic
  5. 0:10therapy is
  6. 0:12why and when we use it and how we set up
  7. 0:14the patient and the device at the end of
  8. 0:17this lecture you will gain confidence in
  9. 0:19selecting the correct programs for basic
  10. 0:22therapies
  11. 0:23navigate through the menu of the biochem
  12. 0:25device and setting up the applicators
  13. 0:28and other accessories
  14. 0:35here we see our already known therapy
  15. 0:37concept scheme again
  16. 0:39basic therapy forms the first step of
  17. 0:42the therapy concept but always after a
  18. 0:44careful anamnesis and examination or
  19. 0:47observation of the patient
  20. 0:49the therapy concept prepares the body
  21. 0:52towards self-regulation step by step
  22. 0:55these steps may be done in one session
  23. 0:57or may be divided in several sessions
  24. 1:00sessions may be performed every one to
  25. 1:02three days if it is an acute patient or
  26. 1:06every 7 to 14 days with patients
  27. 1:09exhibiting chronic problems
  28. 1:11in the rest of this video we will look
  29. 1:14at basic therapy in more detail
  30. 1:21basic therapy is important because it
  31. 1:23prepares the patient for the rest of the
  32. 1:25therapy
  33. 1:26basic therapy with its corresponding
  34. 1:28basic programs adjusts the energy level
  35. 1:31of the body and that which is available
  36. 1:34to the patient
  37. 1:36this helps adjust energetic capacities
  38. 1:38with which the body can work with later
  39. 1:41on in further therapy steps
  40. 1:44in a basic therapy the patient receives
  41. 1:46their own physiologic
  42. 1:48and inverted pathological frequencies
  43. 1:51the aim is to improve the patient's
  44. 1:54general condition and the capacities of
  45. 1:56the body's own regulatory system
  46. 2:00the regulatory capacities are stimulated
  47. 2:02so that the regulation is improved for
  48. 2:04the more targeted follow
  49. 2:06therapies there are various basic
  50. 2:09therapy programs which can be selected
  51. 2:11for the patient
  52. 2:13basic programs are selecting depending
  53. 2:15on the patient's condition and their
  54. 2:18energy levels at the time of treatment
  55. 2:23chronic patients will typically have low
  56. 2:26energy levels
  57. 2:27acute patients and those in an
  58. 2:29inflammatory state will typically have
  59. 2:32high energy levels
  60. 2:33in order to be able to treat the
  61. 2:35patient's conditions more effectively it
  62. 2:38is useful to try to return the body's
  63. 2:40energetic levels to within the normal
  64. 2:42range
  65. 2:43it means that the regulatory system is
  66. 2:46in the best possible state to then deal
  67. 2:48with an action
  68. 2:49the later therapy steps
  69. 2:52here we see the different basic programs
  70. 2:55in the bicomb available for selection we
  71. 2:57see programs for normal energetic state
  72. 3:01young or
  73. 3:03energetic state
  74. 3:05yin or hypo energetic state and also
  75. 3:09programs for reaction blocked patients
  76. 3:11and exhausted patients
  77. 3:14in addition to the program descriptions
  78. 3:16we also see cv values
  79. 3:18cv stands for conductance value
  80. 3:22and this is a more accurate way of
  81. 3:25determining the patient's energetic
  82. 3:27state than simply observing the patient
  83. 3:30conductance value testing can be done
  84. 3:32easily with the bicom and we will look
  85. 3:35at this in more detail now
  86. 3:46here we see the natural energy levels of
  87. 3:49the body throughout the day along with
  88. 3:51the related conductance values
  89. 3:54by measuring the body's energy levels
  90. 3:57which we will discover more about very
  91. 3:59soon it was discovered that the body's
  92. 4:02energy levels are lower during the night
  93. 4:05reach a normal level between 8 in the
  94. 4:07morning and 8 in the evening and start
  95. 4:10to fall again after 10 in the evening
  96. 4:13this is the basis for the normal energy
  97. 4:16level values
  98. 4:17which are used in the conductance value
  99. 4:20scale from this picture it is also
  100. 4:22important to note that the best time to
  101. 4:24do therapies on a patient is from a in
  102. 4:27the morning to 8 in the evening
  103. 4:30in case you do therapies outside of that
  104. 4:32time frame
  105. 4:33this graph and body's energy levels
  106. 4:36should be taken into consideration
  107. 4:41here we see the conductance value scale
  108. 4:43which you will find also on your bicom
  109. 4:45optima device
  110. 4:47please note that with the biker mobile
  111. 4:49device there is no separate scale
  112. 4:51display and conductancy value
  113. 4:53measurements will show on the main
  114. 4:55screen only when conducting esting
  115. 4:59a conductance value of 80 to 89 is
  116. 5:03considered normal here on the scale it
  117. 5:05is highlighted in yellow
  118. 5:08it represents a patient with a normal
  119. 5:10energetic situation in the body
  120. 5:12a value below 80
  121. 5:15on scale it is highlighted in blue
  122. 5:18shows where the energetic capacities of
  123. 5:20the patient start to drop
  124. 5:22values below 80 are chronic conditions
  125. 5:26in chinese medicine that is a yin state
  126. 5:29of energy levels in the body
  127. 5:31medically we talk about osis conditions
  128. 5:34like arthrosis
  129. 5:36spondylosis sarcoidosis and so on
  130. 5:40we deal with situations that are
  131. 5:42prolonged and going on too long in the
  132. 5:44body it means that the body won't have
  133. 5:47enough energetic capacity to modulate
  134. 5:50and work with bio-resonance frequencies
  135. 5:53and to deal with extended bicone therapy
  136. 5:57such patients will need longer to
  137. 5:59respond to the treatment
  138. 6:01what we can do is increase the energy
  139. 6:04levels and regulatory capacities by
  140. 6:06means of basic therapy
  141. 6:09the lower the conductance value the
  142. 6:11stronger the energetic deficit is and
  143. 6:14the greater the need to help the body
  144. 6:16with basic therapies
  145. 6:19value above 90
  146. 6:22which is here highlighted in orange
  147. 6:25shows a strong energetic situation in
  148. 6:27the body
  149. 6:28such patients react hypersensitively to
  150. 6:32environmental stimuli it is like their
  151. 6:35bodies are on constant adrenaline and we
  152. 6:38have to calm them down by means of basic
  153. 6:40therapy
  154. 6:42too much energy in the body cannot
  155. 6:44produce good results
  156. 6:46it is like
  157. 6:48imagine a room which is equivalent to
  158. 6:51the body
  159. 6:52full of people who are in this case the
  160. 6:55body cells
  161. 6:56screaming one over the other total chaos
  162. 7:00one has to inflict a lot of order to
  163. 7:02calm the situation down in order to give
  164. 7:05further instructions
  165. 7:07and that is in our case further
  166. 7:09therapies
  167. 7:11our aim as therapists is to bring the
  168. 7:14patient into normal energetic state to
  169. 7:17be able to continue with further
  170. 7:19therapeutic steps
  171. 7:21during a conductancy value test we are
  172. 7:23measuring the conductivity of the skin
  173. 7:27inflammation and high energy levels are
  174. 7:30accompanied by exudates water retentions
  175. 7:33in the tissues lymph and immune cells
  176. 7:35activation and by the law of physics we
  177. 7:38know
  178. 7:39and that water conducts a current and
  179. 7:42consequently the conductance values are
  180. 7:44high for patients in this state as the
  181. 7:47body more easily conducts the electric
  182. 7:50current
  183. 7:51with chronic conditions and low energy
  184. 7:54levels the main factor is too little
  185. 7:56water but also lots of connective tissue
  186. 8:00consecutively the body does not conduct
  187. 8:03a current with ease therefore the
  188. 8:05conductance values are lower
  189. 8:09the bicom device includes all the
  190. 8:11equipment needed to perform a
  191. 8:13conductance value test this is the
  192. 8:15equipment that allows us to perform the
  193. 8:18conductance value measurement it
  194. 8:20consists of two parts the test and
  195. 8:22therapy still is connected to a dark
  196. 8:24blue cable with a light blue cable
  197. 8:27attached for connecting a cylindrical
  198. 8:29hand applicator
  199. 8:31a second hand applicator is also
  200. 8:33required but should not be connected to
  201. 8:36anything
  202. 8:37the test and therapy stillus cable is
  203. 8:40connected with a 7-pin plug to the
  204. 8:42connecting socket at the back
  205. 8:45or side of the bi-com optima device
  206. 8:48it should be screwed tight
  207. 8:51one cylindrical applicator is then
  208. 8:54attached to the free blue cable with the
  209. 8:57second cylindrical applicator left
  210. 8:59unconnected to anything
  211. 9:04now we will learn how to determine the
  212. 9:06conductance value with the mentioned
  213. 9:08equipment it is done like it is shown on
  214. 9:11the picture
  215. 9:13first we make sure that the hands are
  216. 9:15warm and not too dry nor too wet
  217. 9:19dry hands give falsely low value
  218. 9:23and sweaty hands give falsely higher
  219. 9:25values
  220. 9:26correspondingly we make them wet or we
  221. 9:29dry them
  222. 9:31the person to be tested holds in each
  223. 9:33hand a cylindrical hand applicator
  224. 9:36one of the hand applicators is connected
  225. 9:38to the blue cable of the test part
  226. 9:42the other is not connected to anything
  227. 9:44this forms a closed circuit with the
  228. 9:47patient in the middle
  229. 9:49the therapist presses the point of the
  230. 9:51test and therapy stillus to the whole of
  231. 9:53the cylindrical hand applicator that is
  232. 9:56not connected
  233. 9:58on the test scale the conductance value
  234. 10:00can then be read
  235. 10:02please note that
  236. 10:04with the biocom optima mobile device a
  237. 10:07measuring bar appears on the top left
  238. 10:10hand side of the main display
  239. 10:13the number that is reached on the scale
  240. 10:16is our conductance value and the value
  241. 10:18that will help us determine the basic
  242. 10:21program
  243. 10:22now we will look at a video
  244. 10:24demonstration
  245. 10:39[Music]
  246. 10:47now pause this training video and make
  247. 10:49these steps by yourself
  248. 10:57now we know the conductance value we can
  249. 10:59select the appropriate basic therapy in
  250. 11:02the bicom on the following slides we
  251. 11:04will learn how to navigate through the
  252. 11:06menus
  253. 11:07while you listen to this training video
  254. 11:09explore and apply the information
  255. 11:11already on your device
  256. 11:17the first menu that we see on the screen
  257. 11:20is the main menu we come to this screen
  258. 11:22when the device starts or if we press
  259. 11:25the button home
  260. 11:27so at this point we need to press number
  261. 11:29one which is basic programs i strongly
  262. 11:32advise you to apply these steps always
  263. 11:35with your device as we proceed with this
  264. 11:37video
  265. 11:42the next menu that opens describes
  266. 11:44different options for basic programs
  267. 11:47when we choose number one we go into
  268. 11:50standard basic programs
  269. 11:52which we will also do in this case
  270. 11:55number two represents extended basic
  271. 11:57programs that would develop according to
  272. 11:59my cell riffle and contain specific
  273. 12:02adjustments of parameters which prolong
  274. 12:05the basic therapy up to 30 minutes
  275. 12:09the programs are very efficient and can
  276. 12:11be chosen as alternative basic programs
  277. 12:14especially for chronic patients
  278. 12:17in some cases you may also see here an
  279. 12:19option for standardized basis systematic
  280. 12:23this is a protocol for chronic patients
  281. 12:25and will be explained in a separate
  282. 12:27video
  283. 12:28programs before the year 2009 are also
  284. 12:31listed and these are older versions of
  285. 12:34basic programs
  286. 12:36they might be still in use by some
  287. 12:38advanced and long-standing therapists
  288. 12:41who are used to their way of work
  289. 12:44for starting with biochem therapy it is
  290. 12:46however recommended to start with
  291. 12:48standard basic programs and that is
  292. 12:51under number one so press one
  293. 12:56next we reach a menu where the different
  294. 12:59energetic states are listed together
  295. 13:01with the conductance value
  296. 13:04which is of course shortened with
  297. 13:06capital letters cv
  298. 13:08the therapy selects the correct number
  299. 13:11according to the conductance value of
  300. 13:13the patient's energetic state
  301. 13:16if a patient continues to come for
  302. 13:18treatment has no change in physical
  303. 13:20condition whatsoever
  304. 13:22a therapist may run number four in this
  305. 13:25menu that is basic therapy for reaction
  306. 13:28blocked patients
  307. 13:30let's say our patient had a conductance
  308. 13:33value 78 so we press number three which
  309. 13:36is the corresponding basic program
  310. 13:44after pressing the correct program we
  311. 13:47enter the menu that describes the
  312. 13:49following
  313. 13:50the five-digit number represents the
  314. 13:52program sequence belonging to that basic
  315. 13:55program
  316. 13:56it also contains its name which is basic
  317. 13:59program for patients in in-state with a
  318. 14:01cv of
  319. 14:0272-79
  320. 14:04this menu also offers information about
  321. 14:06therapy mode which is
  322. 14:09h d i in this case
  323. 14:12next we have the option to learn how to
  324. 14:14place the applicators to do that scroll
  325. 14:17with the arrow button
  326. 14:19to the option show applicators and then
  327. 14:21press e for enter
  328. 14:23this menu also offers all the programs
  329. 14:26that are contained in this program
  330. 14:28sequence
  331. 14:29those are three one three two this is
  332. 14:32four digit number that represents low
  333. 14:34frequency program
  334. 14:36and one three two program that is a
  335. 14:38three digit program that presents normal
  336. 14:41frequency
  337. 14:43and now let's go back to the option show
  338. 14:45applicators to see what it off or what
  339. 14:48it offers us so we scroll to show
  340. 14:50applicators and press e
  341. 14:55the next menu gives us the information
  342. 14:57about where to place the input
  343. 15:00applicators
  344. 15:01as a short reminder input applicator
  345. 15:03sends the frequency waves from the body
  346. 15:06into the biocom device and is connected
  347. 15:08with black cable
  348. 15:11while doing the basic program the
  349. 15:13patient has their left hand on the
  350. 15:15multi-layer hand applicator connected
  351. 15:18with black cable to see the output press
  352. 15:21enter again
  353. 15:25the next menu shows where to put the
  354. 15:27output applicator here the output output
  355. 15:30is the modulation mat and should be
  356. 15:32placed as shown that is on the back
  357. 15:35this is how the therapeutic frequencies
  358. 15:37are transferred to the patient to
  359. 15:39continue just press enter
  360. 15:44now we come to the final steps of
  361. 15:46setting up our basic therapy what is
  362. 15:49still needed and is considered a very
  363. 15:51important part is to fill the input and
  364. 15:53output cups and add a chip to the memory
  365. 15:56device if desired
  366. 16:02here the input cup should be filled with
  367. 16:05a secretion or excretion from the
  368. 16:07patient saliva is an optimum sample
  369. 16:09material and is recommended for basic
  370. 16:12therapy as saliva is basic and easily
  371. 16:15available
  372. 16:16for obtaining the patient saliva sample
  373. 16:19it is best to use a cotton swab or small
  374. 16:22cotton pad the patient can spit on the
  375. 16:25pad or rub the swab around the mouth and
  376. 16:27put it into the glass insert by
  377. 16:29themselves
  378. 16:31then the therapist inserts the glass
  379. 16:33into the input cup make sure to not put
  380. 16:38patient samples into the cups without
  381. 16:40the use of the glass inserts in general
  382. 16:43the more patient's frequency information
  383. 16:45we include into the virus and circle the
  384. 16:48better
  385. 16:49so for many programs multiple sample
  386. 16:51mediums may be recommended
  387. 16:54on this display we we are also reminded
  388. 16:56to put a chip into the memory device as
  389. 16:59well as bicone trace elements or oil
  390. 17:02into the output curve
  391. 17:03the more support we include to the
  392. 17:06patient after the therapy the better the
  393. 17:08result
  394. 17:11now we are all set to run the basic
  395. 17:14program therefore you have to press
  396. 17:16enter
  397. 17:20and after
  398. 17:21that you see an overview again and press
  399. 17:24the button start to continue
  400. 17:29on the display you will be reminded if
  401. 17:32you did all of the activities sofa
  402. 17:34mentioned that is did you place the
  403. 17:36applicators are the input and output
  404. 17:38cups filled is chip inserted you will
  405. 17:42also be asked about channel 2 which we
  406. 17:44will cover in one of the next webinars
  407. 17:47but have in mind that channel 2 is
  408. 17:49filled and activated prior to starting
  409. 17:52the program so if all of the answers are
  410. 17:55yes press the start button again
  411. 18:00the basic program starts to run and this
  412. 18:03menu shows the green colored program
  413. 18:05number is the one that is running at
  414. 18:08that time below are all the
  415. 18:10specifications of that program including
  416. 18:13the remaining time left for that program
  417. 18:16at the upper right corner the remaining
  418. 18:19time is shown for the whole program
  419. 18:21sequence
  420. 18:22on the bottom of the screen there is a
  421. 18:24corresponding frequency band in this
  422. 18:27case the low frequency band and moving
  423. 18:30cursor
  424. 18:31because the low frequency band a program
  425. 18:34is running the cursor is colored orange
  426. 18:38if a normal frequency program is running
  427. 18:41the cursor will turn green
  428. 18:44to move to the next program just use
  429. 18:46arrow buttons or wait till this program
  430. 18:49is over and it will switch automatically
  431. 18:52with a beep signal
  432. 18:54to stop the therapy
  433. 18:57earlier you may press the start button
  434. 19:00again
  435. 19:04here is an overview of the whole setup
  436. 19:07for doing the basic program the left
  437. 19:09hand is placed as an input on the
  438. 19:12multi-layered applicator which is
  439. 19:14connected with black cable
  440. 19:17the modulation mat as the output is
  441. 19:20placed along the
  442. 19:21back the input cup is enriched with a
  443. 19:24sample material from the patient which
  444. 19:26is stored in insertion glass or ampoule
  445. 19:30saliva is recommended here
  446. 19:32in the output cup there is a bicon trace
  447. 19:35elements or oil
  448. 19:37a bicone chip might be added to memory
  449. 19:39device as well
  450. 19:42with this video we have learned the
  451. 19:44first step of the biochem treatment
  452. 19:46concept that is preparing the patient
  453. 19:48with basic therapy
  454. 19:51after basic therapy the patient is now
  455. 19:53energetically more able to start facing
  456. 19:56further obstacles
  457. 19:58learning how to prepare the patient for
  458. 20:00later steps is vital for successful
  459. 20:02treatment outcomes
  460. 20:04you are invited to practice the steps
  461. 20:06learned in this video before you move to
  462. 20:09the next one
  463. 20:15so after you feel confident in setting
  464. 20:17up the basic therapy i would kindly
  465. 20:20invite you to proceed to the next video
  466. 20:22which is blockages and supporting the
  467. 20:24elimination organs
  468. 20:27there we will discuss the second and
  469. 20:29third steps of the therapy concept in
  470. 20:31detail
  471. 20:32we will look at the importance of
  472. 20:34including these steps and recommended
  473. 20:36programs for the therapy

About this transcript

This page contains the full transcript of BICOM basic training 4 Basic therapy by Education Institut Bioresonance, generated from the public captions YouTube serves with the video. The transcript has 2,727 words across 473 segments, with the original timestamps preserved so you can click any line to jump to that moment in the embedded player.

What you can do with it

Use the transcript to take notes, quote the speaker, build a study guide, generate a summary with ChatGPT or Claude via the YouTube Summary tool, or export it as a timed subtitle file with YouTube to SRT. You can also re-open it in the transcriber to translate the transcript into 100+ languages.

Free YouTube transcript tool

YouTube2Text is a free YouTube transcript generator — no signup, no daily limit. Paste any YouTube link and get the full transcript instantly, with timestamps, click-to-jump, translation to 100+ languages, AI prompts for ChatGPT, Claude, and Gemini, and exports to TXT, SRT, VTT, or Markdown.