  1. 0:00I welcome you to the webinar on seismic
  2. 0:06analysis using the response spectrum
  3. 0:08method. My name is Daniel Gas. I am
  4. 0:14supported today by Ms. Gabriel Müller
  5. 0:16and Mr. Dirk Menenger, who will be
  6. 0:17happy to answer your questions via the
  7. 0:19webinar panel on the right side of your
  8. 0:22screen. Today, we will focus
  9. 0:26exclusively on the actual seismic
  10. 0:29calculation. We will hold another
  11. 0:33webinar on March 30th regarding the
  12. 0:35evaluation of the results. We typically
  13. 0:41apply the response spectrum method to a
  14. 0:43spatial building model for which we
  15. 0:45perform a modal analysis. The standard
  16. 0:52stipulates that we should consider
  17. 0:54enough eigenmodes so that the sum of
  18. 0:56the modal masses—that is, the masses
  19. 0:59of the single-degree-of-freedom systems
  20. 1:01shown here—amounts to at least 90%of
  21. 1:03the total building mass. I will say
  22. 1:10more about that later. Based on the
  23. 1:16site parameters, namely the seismic
  24. 1:18zone and the soil class, we select a
  25. 1:21response spectrum. From this response
  26. 1:29spectrum and other structure-dependent
  27. 1:31parameters, such as the importance
  28. 1:33factor and behavior factor, we
  29. 1:34determine the design spectrum. Using
  30. 1:43the previously calculated natural
  31. 1:45frequencies, we enter this design
  32. 1:47spectrum to determine the maximum
  33. 1:48accelerations of the modal
  34. 1:50single-degree-of-freedom systems. By
  35. 1:57reversing the modal analysis, we obtain
  36. 1:59accelerations for the entire model. We
  37. 2:05can multiply these accelerations by the
  38. 2:07masses to obtain the seismic forces.
  39. 2:14Finally, we perform a static analysis
  40. 2:16taking these seismic forces into
  41. 2:18account and design the structural
  42. 2:20components. To implement this in Axis
  43. 2:29VM, we start in the Loads tab and first
  44. 2:32create a load combination. We will use
  45. 2:39this load combination later to
  46. 2:41determine the masses. We can name this
  47. 2:49load combination whatever we like. The
  48. 2:54type we select does not fundamentally
  49. 2:56matter. It only serves to group the
  50. 3:01load combinations if we create several.
  51. 3:08Technically, a user-defined combination
  52. 3:10is correct. We consider all permanent
  53. 3:16loads with a factor of 1.0 and variable
  54. 3:21loads with the factor PSI 2. This means
  55. 3:31we consider all permanent loads at
  56. 3:33their characteristic value and variable
  57. 3:35loads at their quasi-permanent portion.
  58. 3:44We neglect all loads here that are not
  59. 3:47caused by masses, e.g., wind loads, or
  60. 3:49that do not have a quasi-permanent
  61. 3:51portion. In many regions, this refers
  62. 3:59to snow loads, for example. We can now
  63. 4:07start the vibration analysis and, in
  64. 4:15the calculation parameters, select the
  65. 4:18load combination we just created and
  66. 4:20convert these loads into masses.
  67. 4:28Unfortunately, we cannot determine the
  68. 4:30number of vibration modes required in
  69. 4:32advance. We must make an assumption.
  70. 4:38Nine eigenmodes are set as the default
  71. 4:41value. I will leave it as it is. On the
  72. 4:49right side, we have further options.
  73. 4:55For one, we can neglect certain mass
  74. 4:57components. In this case, as in very
  75. 5:02many cases, I would like to neglect the
  76. 5:04vertical vibration component. I am
  77. 5:09therefore deactivating the mass
  78. 5:11component MZ. At the very bottom, I
  79. 5:19select which masses should be
  80. 5:21considered. Uh, I can consider all
  81. 5:26masses. That is the default setting. I
  82. 5:31can consider masses starting from a
  83. 5:33certain ratio. Or if I work with the
  84. 5:40floor identification at the top left,
  85. 5:42uh, I can select the masses above which
  86. 5:44floor, uh, I would like to consider. By
  87. 5:55considering or neglecting masses below
  88. 5:57a certain ratio, I define the clamping
  89. 5:59horizon. This means my entire building
  90. 6:06mass is calculated above the clamping
  91. 6:09horizon. With this, I can start the
  92. 6:16vibration calculation. In this case, it
  93. 6:20takes about one and a half minutes,
  94. 6:22which I would like to skip. I will
  95. 6:28therefore open another model. We have
  96. 6:35the results of the vibration analysis
  97. 6:37here. As result values, we receive
  98. 6:44exclusively deformations. These
  99. 6:48deformations are dimensionless. You see
  100. 6:52no unit in the coordinate window.
  101. 6:57Natural vibrations do not provide us
  102. 6:59with an absolute displacement. They
  103. 7:03only provide us with ratios between the
  104. 7:06displacement of individual nodes. We
  105. 7:10have not defined an absolute magnitude
  106. 7:13of excitation. Therefore, no absolute
  107. 7:17displacement can be determined. After
  108. 7:25the actual earthquake calculation, we
  109. 7:27will obtain deformations that do indeed
  110. 7:29have a dimension. In the very first
  111. 7:41step, I want to display the deformed
  112. 7:43model to verify these natural modes. I
  113. 7:52increase the magnification factor to
  114. 7:54see better how the building deforms.
  115. 8:03The first natural mode, as Axis VM
  116. 8:05designates it, is the first natural
  117. 8:08mode according to physical definition.
  118. 8:13That is, it is the natural mode with
  119. 8:16the lowest natural frequency, in this
  120. 8:18case 3.4 Hz. I can look at the other
  121. 8:24vibration modes. And I can consider, at
  122. 8:33least qualitatively, whether these
  123. 8:35natural vibrations are plausible,
  124. 8:37whether the building can even vibrate
  125. 8:39this way. I am now opening the table
  126. 8:49view. The table for the mass
  127. 8:54participation of the natural modes is
  128. 8:56opened automatically. We see here the
  129. 9:01share of the modal mass in the total
  130. 9:03building mass for each natural mode. As
  131. 9:11mentioned, we should reach at least 90%
  132. 9:14, which means 0.9 in this case. I have
  133. 9:21the option to switch off natural modes.
  134. 9:27I do not need them to reach these 90%.
  135. 9:33Thus, no earthquake loads are
  136. 9:35calculated for the inactive natural
  137. 9:37modes. I can thereby reduce the
  138. 9:41computational effort somewhat. In this
  139. 9:47respect, the standard differs from the
  140. 9:49Eurocode. The standard stipulates that
  141. 9:56we should reach this 90%modal mass
  142. 9:58participation without further
  143. 10:00conditions. The Eurocode goes a step
  144. 10:11further here and says we should reach
  145. 10:13this 90%modal mass participation, or at
  146. 10:16least consider all natural modes that
  147. 10:18individually have a modal mass
  148. 10:20participation of more than 5%. Uh, that
  149. 10:31is hard to verify if we should not
  150. 10:34reach this 90%modal mass participation.
  151. 10:41Uh, we do not know what shares the 12th
  152. 10:44or 15th natural mode might possess. Uh,
  153. 10:52but we can assume that these modal mass
  154. 10:54shares tend to decrease toward higher
  155. 10:56natural modes. It is not a steady
  156. 11:02decline, but the trend is there. If we
  157. 11:11have calculated 20 eigenmodes and we
  158. 11:13find that from the tenth eigenmode
  159. 11:15onwards no relevant modal mass
  160. 11:17participation is reached, we can assume
  161. 11:19, uh, that we will not have any
  162. 11:21eigenmode with more than a 5%share. The
  163. 11:31Eurocode establishes a second condition
  164. 11:33. If, uh, if we cannot meet this first
  165. 11:40condition, we should at least consider
  166. 11:43all eigenmodes that have an
  167. 11:45eigenfrequency below 5 Hz, uh. As a
  168. 11:53minimum, however, we should consider
  169. 11:55the square root of the number of floors
  170. 11:58in eigenmodes. You see the eighth and
  171. 12:05ninth eigenmode here in the eight. Here
  172. 12:08the eigenfrequency is displayed in red.
  173. 12:16This is more or less typical for higher
  174. 12:18eigenmodes and means nothing other than
  175. 12:20that the numerical error in the
  176. 12:22calculation of this eigenmode is
  177. 12:24greater than 10 to the power of -5.
  178. 12:34These eigenmodes are no longer 100%
  179. 12:37reliable. We have a relatively large
  180. 12:43possible deviation here due to the
  181. 12:45iterative calculation. I return to the
  182. 12:54load definition and under load cases
  183. 13:01and load case groups I can create an
  184. 13:03earthquake load case. In this
  185. 13:11earthquake load case, I can define the
  186. 13:13earthquake load. I must save the model
  187. 13:19first. and now have the option to set
  188. 13:24the earthquake parameters. I select the
  189. 13:31subsoil class I want on the left side.
  190. 13:37I define the design value of the
  191. 13:39horizontal ground acceleration. I
  192. 13:44define the behavior factor. I can enter
  193. 13:50the behavior factor twice. Once the
  194. 13:56behavior factor for calculating
  195. 13:58internal forces and, separately, a
  196. 14:00behavior factor for calculating
  197. 14:02deformation. The standards, both SIA
  198. 14:08and Eurocode, distinguish between these
  199. 14:11two values. or not. You can use the
  200. 14:15same value for both. Next, I define the
  201. 14:22, uh, importance factor and I get, uh,
  202. 14:29the design spectrum. Important, uh, to
  203. 14:34mention: it is the design spectrum, not
  204. 14:36the response spectrum. Uh, compared to
  205. 14:44the SIA standard, there is a difference
  206. 14:46, uh, in this representation, or rather
  207. 14:48two differences. The standard
  208. 14:54normalizes the time axis
  209. 14:56logarithmically or uses a logarithmic
  210. 14:58time axis. This changes the, uh, image
  211. 15:04of the design spectrum. And you see the
  212. 15:11note here: the design spectrum, as
  213. 15:13shown here, is not normalized to
  214. 15:15gravity. This means that compared to
  215. 15:23the design spectra you calculate
  216. 15:25according to SIA 261, you get a
  217. 15:27difference of a factor of 10. When I
  218. 15:39confirm the entry of this, uh,
  219. 15:41earthquake load, I receive a warning.
  220. 15:47The sum of the modal mass participation
  221. 15:49in the Z-direction is less than 90%.
  222. 15:56This is because we, uh, have neglected
  223. 15:58the, uh, vertical vibration component.
  224. 16:05I can ignore this warning and carry out
  225. 16:07the earthquake calculation in exactly
  226. 16:09the same way. I will go back to the
  227. 16:15earthquake parameters once more. I have
  228. 16:20a few other options here that I would
  229. 16:21like to show. If I have calculated the
  230. 16:29vertical vibration component, I have
  231. 16:31the option to consider the vertical
  232. 16:33accelerations. I can independently
  233. 16:39define the earthquake parameters here.
  234. 16:47You can refer to the code for how to
  235. 16:49determine the earthquake parameters for
  236. 16:51vertical seismic action. Under the
  237. 17:02Torsion Effect tab, I have the option
  238. 17:05to apply torsion due to accidental
  239. 17:07eccentricity. This means the seismic
  240. 17:14loads are shifted by 5%of the building
  241. 17:16width, once to the left and once to the
  242. 17:18right. Uh. For this, I must specify the
  243. 17:27levels at which the individual floor
  244. 17:29slabs are located. If I am using story
  245. 17:37detection, the individual stories are
  246. 17:39already listed here. Which I should
  247. 17:44still do. I can delete the stories
  248. 17:51below the base level, so the lowest
  249. 17:53story represents the level of my base.
  250. 18:03If I am not using story detection, this
  251. 18:05window is empty by default. I have the
  252. 18:12option to enter the levels manually or
  253. 18:14import them from the model. In this
  254. 18:18case, I define one point at each height
  255. 18:24of a floor slab. In doing so, I ignore
  256. 18:30these stair landings, for example. They
  257. 18:35do not represent a full story in terms
  258. 18:37of seismic calculation. Whether I want
  259. 18:43to specify the slab for this elevator
  260. 18:45overrun or not is essentially up to me.
  261. 18:53In the last tab, I can further adjust
  262. 18:55the calculation. The combination of
  263. 19:02modal responses refers to the
  264. 19:03combination of individual natural
  265. 19:05vibrations. According to the code, both
  266. 19:15SIA and Eurocode specify the SRSS
  267. 19:17method, which stands for Square Root of
  268. 19:19Sum of Squares. We have a second option
  269. 19:30. We can combine the earthquake or
  270. 19:36natural modes using CQC, the Complete
  271. 19:39Quadratic Combination. In this method,
  272. 19:47each natural mode is combined with
  273. 19:49every other one using an additional
  274. 19:51factor. You can find the definition of
  275. 19:56this factor in the Axis VM
  276. 19:58documentation. This CQC method has a
  277. 20:05clear advantage over SRSS. It provides
  278. 20:12significantly more realistic results in
  279. 20:14the case of dependent natural modes.
  280. 20:19Dependent natural modes are natural
  281. 20:21modes with very similar natural
  282. 20:23frequencies. If the natural frequencies
  283. 20:29of two natural modes are close to each
  284. 20:31other, it is practically impossible to
  285. 20:34excite one mode on its own. The other
  286. 20:40natural mode will always vibrate
  287. 20:41slightly as well. The default setting
  288. 20:48is automatic. This means the program
  289. 20:52checks if dependent natural modes exist
  290. 20:54. If so, the CQC method is used;
  291. 20:58otherwise, it is combined according to
  292. 21:01SRSS. It is also worth noting that if
  293. 21:08the natural modes are completely
  294. 21:10independent—meaning the natural
  295. 21:12frequencies are theoretically
  296. 21:14infinitely far apart—both methods are
  297. 21:16absolutely identical. In the lower
  298. 21:24section, we combine the components of
  299. 21:26the seismic excitation. This means we
  300. 21:29combine the directions. According to
  301. 21:34SIA, the default is again the SRSS
  302. 21:37method. However, you can also choose
  303. 21:42the so-called 30%rule. We apply the
  304. 21:48earthquake action at 100%in one
  305. 21:50direction and 30%in each of the other
  306. 21:52two directions. This combination method
  307. 22:00originates from the DIN standard.
  308. 22:05According to the Eurocode, both
  309. 22:07combination methods are generally
  310. 22:09permitted. Now, the earthquake loads
  311. 22:20have been calculated. We have received
  312. 22:25a large number of load cases. These
  313. 22:30four load cases, ERa to ERb. System
  314. 22:36load cases. We do not see any loads in
  315. 22:39these load cases. They are used to
  316. 22:44combine the individual earthquake loads
  317. 22:46. We obtain the result of this
  318. 22:53combination in these load cases, ER1 +
  319. 22:56to ER4-. We also do not see any results
  320. 23:03in these load cases. These load cases
  321. 23:07do not contain any loads in the actual
  322. 23:09sense. However, they will contain
  323. 23:12results later on. If we neglect the
  324. 23:21torsion due to accidental eccentricity,
  325. 23:24we would not have eight load cases here
  326. 23:26, but only two. They are called ER +
  327. 23:31and ER-. The remaining load cases
  328. 23:38contain the loads from the individual
  329. 23:40natural vibrations. We can see loads
  330. 23:47here. We can also label them, and you
  331. 23:53will notice that these earthquake loads
  332. 23:55are very small. We are in the order of
  333. 24:02magnitude of half a kilonewton to one
  334. 24:04kilonewton per individual load. That is
  335. 24:09absolutely normal. We receive a
  336. 24:14multitude of loads across a multitude
  337. 24:16of load cases. In the end, it still
  338. 24:21results in a significant earthquake
  339. 24:23load. The load case I am looking at
  340. 24:31right now contains the earthquake loads
  341. 24:33from the second natural vibration due
  342. 24:35to the mass component in the
  343. 24:36X-direction. Due to an asymmetry in the
  344. 24:45floor plan—that is, due to torsion
  345. 24:47resulting from actual eccentricity—I
  346. 24:50can also obtain earthquake loads in the
  347. 24:52Y-direction from the mass component in
  348. 24:54the X-direction. Finally, I will now
  349. 25:09perform a static calculation and I will
  350. 25:15obtain the results from the earthquake
  351. 25:16analysis. I would like to skip that as
  352. 25:22well. The static calculation takes
  353. 25:27about 30 to 40 seconds in this example.
  354. 25:36Basically, we are already finished with
  355. 25:38the earthquake analysis now and can
  356. 25:40evaluate the results. What is also
  357. 25:49important to mention is that when we
  358. 25:51perform the static calculation, we must
  359. 25:54choose a linear static analysis.
  360. 26:01Unfortunately, it is not possible to
  361. 26:03perform a non-linear earthquake
  362. 26:05analysis using the response spectrum
  363. 26:07method. This means we also do not have
  364. 26:15the option to consider non-linearities,
  365. 26:17such as tension cut-off. I will go into
  366. 26:25more detail about that in the second
  367. 26:27part of this webinar. Well, the
  368. 26:42governing results we receive here
  369. 26:43include both the results of the static
  370. 26:46calculation and the results of the
  371. 26:47earthquake analysis. I would now like
  372. 27:01to go into a few details. First, I
  373. 27:07would like to say something about the
  374. 27:09model itself. In this case, I entered
  375. 27:16the model just as I would for a static
  376. 27:18calculation. It is important that I set
  377. 27:26the hinge conditions realistically.
  378. 27:32This means that for these masonry walls
  379. 27:34, I have defined a moment release. This
  380. 27:43means I have fixed all displacements
  381. 27:45and released all rotations, which
  382. 27:47allows the masonry walls to transfer
  383. 27:49horizontal forces as well. If I do not
  384. 27:58want that, I release the displacement
  385. 28:00along the hinge line, meaning along the
  386. 28:02top of the wall. This means I set the
  387. 28:09stiffness kx to 0. This way, the slab
  388. 28:16can slide along the wall without
  389. 28:18resistance, and I do not transfer any
  390. 28:20horizontal forces to the wall. It is
  391. 28:27important that I make this adjustment
  392. 28:28either at the top or at the bottom. If
  393. 28:35I release this connection at both the
  394. 28:36top and the bottom, my wall will shift
  395. 28:38through the building without resistance
  396. 28:40. And the model becomes unstable. This
  397. 28:47means that in the end, the calculation
  398. 28:49is no longer possible. It is also
  399. 28:58important to correctly model the
  400. 28:59connections, especially for these stair
  401. 29:01flights. Such a stair flight represents
  402. 29:09a diagonal connection between two
  403. 29:11floors. In this case, it is indirect,
  404. 29:15via the stair landing. And I get a sort
  405. 29:21of wind bracing that can stiffen the
  406. 29:22building quite significantly. In this
  407. 29:30case, I have also defined a moment
  408. 29:32hinge at the top and bottom. And on the
  409. 29:40side, I have defined an edge hinge
  410. 29:41without significant stiffnesses. This
  411. 29:54means I have mostly set the stiffnesses
  412. 29:57to 0, and for the stiffness KY, meaning
  413. 29:59the transmission of forces in the plane
  414. 30:02of the stair flight, I have set a
  415. 30:04minimum stiffness of 100 kN per meter
  416. 30:06per meter. This stiffness is so small
  417. 30:17that I can consider the connection as
  418. 30:19structurally non-existent. It is not
  419. 30:26possible to define edge hinges without
  420. 30:28any stiffness at all. Therefore, I must
  421. 30:33provide a minimum value somewhere.
  422. 30:38Essentially, however, with this edge
  423. 30:40hinge, I am modeling a complete
  424. 30:42separation between the wall and the
  425. 30:44stair flight. I would like to add
  426. 30:52something else regarding the
  427. 30:54stiffnesses. It is crucial that we
  428. 30:58model realistic stiffnesses for the
  429. 31:00seismic calculation. We previously
  430. 31:07performed the seismic calculation using
  431. 31:09the same stiffnesses we use for static
  432. 31:11analysis. In the settings menu, however
  433. 31:19, I also have the option to define a
  434. 31:22stiffness reduction. Here I can specify
  435. 31:31factors to reduce the stiffness of
  436. 31:33individual structural elements. In the
  437. 31:38vast majority of cases, the stiffness
  438. 31:40of the walls is the deciding factor.
  439. 31:44This means it has by far the greatest
  440. 31:47influence. Which value you use here is
  441. 31:53more or less up to you. The standards
  442. 31:59do not specify a fixed stiffness
  443. 32:01reduction. In the literature, you will
  444. 32:07generally find values here between
  445. 32:10approximately 0.5 and nearly 1.0. I am
  446. 32:18choosing a stiffness reduction of 0.7
  447. 32:20here, as proposed by Professor Bachmann
  448. 32:27from the ETH in Zurich. When I now
  449. 32:37perform the natural vibration
  450. 32:39calculation, it is absolutely essential
  451. 32:41that I also take this reduced stiffness
  452. 32:43into account. As soon as I set the
  453. 32:51stiffness reduction, it is active by
  454. 32:53default. However, I highly recommend
  455. 33:00that you check this again. If you
  456. 33:05select original stiffness, the
  457. 33:07stiffness reduction is neglected. In
  458. 33:25this example, we have set the restraint
  459. 33:27level at the ceiling height above the
  460. 33:29basement. The restraint level is
  461. 33:38usually set at the height of the ground
  462. 33:39level. This means we neglect all loads
  463. 33:52from the basement and also the loads or
  464. 33:54masses acting directly on the basement
  465. 33:56floors. I have tried to represent this
  466. 34:06with colors here. This building has a
  467. 34:12basement that is half above ground
  468. 34:14level on one side. We can represent a
  469. 34:21restraint level not only as a
  470. 34:23horizontal plane. I would also like to
  471. 34:28show you right away how to do that we
  472. 34:37open the Load Cases and Load Case
  473. 34:39Groups dialog and we separate the load
  474. 34:45cases. into a normal self-weight or
  475. 34:53permanent load case and permanent loads
  476. 34:55below the restraint level. And we do
  477. 35:02exactly the same for the variable loads
  478. 35:04. I am hiding everything, I am hiding
  479. 35:18all components that are located above
  480. 35:24the restraint level. In this case, it
  481. 35:31is very easy because I have separated
  482. 35:33the material definition. I can simply
  483. 35:39select the material definition of the
  484. 35:41basement. Another possibility would be
  485. 35:48to mark the corresponding components
  486. 35:50and use this function to display only
  487. 35:52selected elements. I can hide
  488. 35:59everything else. I open the Property
  489. 36:12Editor in the Window menu on the second
  490. 36:18screen. I show the loads and I can, for
  491. 36:28example, select these loads with
  492. 36:30Control A and I can move all loads to
  493. 36:39the second load case. I do exactly the
  494. 36:45same with the variable loads. I mark
  495. 36:52all loads and I move them to the load
  496. 36:54case. Q, variable loads below horizon.
  497. 37:09In my load combination, I set these
  498. 37:11load cases to 0. This means I manually
  499. 37:19neglect the masses below the restraint
  500. 37:21level. It is important that when
  501. 37:27calculating natural vibrations I choose
  502. 37:34the setting "all masses" for the
  503. 37:36considered masses. I have manually
  504. 37:40neglected the masses below the
  505. 37:42restraint level. In the load
  506. 37:46combination, I leave this setting
  507. 37:51unchanged. the masses of these cut-off
  508. 37:56wall sections are still not considered.
  509. 38:09If everything works, then essentially
  510. 38:11everything has been said about seismic
  511. 38:14analysis. However, I would like to show
  512. 38:19you something that can go wrong with
  513. 38:21vibration analysis. I have supplemented
  514. 38:27the model here with wall pieces in the
  515. 38:33stairwell. In this case, local natural
  516. 38:41vibrations occur. We have such an
  517. 38:45example here. In this case, only this
  518. 38:49stairwell wall is vibrating. The rest
  519. 38:56of the building essentially does not
  520. 38:58move. These mode shapes are not
  521. 39:05relevant for seismic analysis. You can
  522. 39:15usually recognize this very well in the
  523. 39:17deformed view, as these local natural
  524. 39:19vibrations typically produce large
  525. 39:21deformations in these vibrating
  526. 39:23components. Under certain circumstances
  527. 39:31, you can highlight this even better
  528. 39:33with the magnification factor. In the
  529. 39:42table of mass participation factors,
  530. 39:44you can easily identify local mode
  531. 39:46shapes because the modal mass
  532. 39:47participation factors are very small.
  533. 39:57You may also get other mode shapes with
  534. 40:00small modal mass participation factors,
  535. 40:02but local mode shapes typically have
  536. 40:04small mass participation. Unfortunately
  537. 40:11, also typical—and this is the
  538. 40:13unpleasant characteristic—local mode
  539. 40:19shapes very often appear in clusters.
  540. 40:25This means that several local mode
  541. 40:27shapes have nearly the same natural
  542. 40:29frequency. If we look at this here, you
  543. 40:39can see it quite well; various
  544. 40:41vibrations of this stairwell wall occur
  545. 40:44at almost—or, down to two decimal
  546. 40:46places, even exactly—the same natural
  547. 40:49frequency. We could basically just
  548. 41:03ignore these local vibrations, but then
  549. 41:05we no longer reach the required 90%mass
  550. 41:08participation. In this case, I wouldn't
  551. 41:17worry too much about it. We are 5%below
  552. 41:23this threshold in the Y direction. Uh.
  553. 41:34Considering that seismic calculation
  554. 41:36does not have the same precision as a
  555. 41:39static calculation anyway, I can
  556. 41:41conclude that 85%is greater than 90%.
  557. 41:50But it can become more extreme, to the
  558. 41:52point where I would no longer want to
  559. 41:53allow it. The simplest approach to deal
  560. 41:59with this is to calculate more mode
  561. 42:01shapes. However, I might need a very
  562. 42:07large number of mode shapes to handle
  563. 42:10these local vibrations or to avoid the
  564. 42:16influence of these local vibrations.
  565. 42:22Another approach is to exclude these
  566. 42:24local vibrations. To do this, I go to
  567. 42:33the Loads tab. I select this wall.
  568. 42:45Let's do this the simple way. Ah, it is
  569. 42:49not a different material either.
  570. 42:53Therefore, I have to select the areas
  571. 42:56individually. I open the property
  572. 43:07editor again and shift this load as
  573. 43:09well. Below the restraint level, so to
  574. 43:20speak. This means I am neglecting the
  575. 43:26loads on the affected components.
  576. 43:44Neglecting the load or assigning the
  577. 43:46mass of a single wall doesn't change
  578. 43:48much in the natural vibrations. But if
  579. 43:56I neglect the masses of all walls, for
  580. 43:58example, then I am making a not
  581. 44:00insignificant error. I can represent
  582. 44:07this mass again by creating an
  583. 44:15additional load case. For this, I
  584. 44:20choose an independent load case.
  585. 44:26Independent load cases are not
  586. 44:27automatically combined with the other
  587. 44:29load cases after the static calculation
  588. 44:31. And now I have the option to apply
  589. 44:40the wall weight at the wall base and
  590. 44:46wall head as a line load and include it
  591. 44:58in the load combination for mass
  592. 45:00determination. This way, the total mass
  593. 45:12we represent is correct, but the
  594. 45:14individual walls that cause local
  595. 45:15vibrations are considered massless and
  596. 45:18therefore can no longer vibrate on
  597. 45:20their own. The local mode shapes no
  598. 45:28longer occur. Finally, I would like to
  599. 45:39make a single remark regarding
  600. 45:40calculation time. The calculation time
  601. 45:47is influenced by various factors. It
  602. 45:53stands to reason that computation time
  603. 45:55depends heavily on the model. The
  604. 46:01larger the model, the longer the
  605. 46:03calculation will take. Uh. However, the
  606. 46:12calculation depends not only on the
  607. 46:14size but also on the complexity of the
  608. 46:16model. I recommend simplifying the
  609. 46:21model as much as possible. This means,
  610. 46:26for instance, if two walls are almost
  611. 46:29touching, I would model them as one.
  612. 46:37This could be the case if the wall
  613. 46:39thickness changes and the outer edge is
  614. 46:41flush; I wouldn't model the wall axes
  615. 46:43offset. Mesh generation also logically
  616. 46:52influences the calculation time. I
  617. 46:58tried this out using this example. I
  618. 47:05obtained very different calculation
  619. 47:06times for different mesh sizes. For
  620. 47:14instance, with a mesh size of half a
  621. 47:16meter, I had to wait almost 13 minutes.
  622. 47:24I wouldn't necessarily recommend this
  623. 47:25mesh size to you. It is relatively fine
  624. 47:31, at least for an entire building. It
  625. 47:37can make sense to mesh individual small
  626. 47:39components with half a meter. On the
  627. 47:49other hand, with a 2-meter mesh, I get
  628. 47:51just over a minute of calculation time,
  629. 47:54and with the maximum possible mesh size
  630. 47:56, I'm under half a minute for the
  631. 47:58vibration analysis. Uh, maximum
  632. 48:05possible. That means, I think I entered
  633. 48:08about 50 meters. Due to the constraints
  634. 48:16at the corners of the components, such
  635. 48:18a large mesh is not even possible. With
  636. 48:27an optimized mesh, that is, with
  637. 48:29different mesh sizes depending on the
  638. 48:31dimensions of the components. In this
  639. 48:37case, between half a meter and I
  640. 48:39believe 1.80 meters, I get a
  641. 48:41calculation time of 1 minute and 40
  642. 48:43seconds. I consider that absolutely
  643. 48:50reasonable for such a building.
  644. 48:57Calculation time is logically also very
  645. 48:59dependent on the system environment.
  646. 49:06Excuse me. Essentially, calculation
  647. 49:12time is influenced by processor
  648. 49:14performance and, up to a certain size,
  649. 49:16by the RAM. I say up to a certain size;
  650. 49:24above 8 GB of RAM, there is hardly any
  651. 49:26noticeable impact. However, below 4 GB
  652. 49:34of RAM, the influence of the memory is
  653. 49:36relatively high. Another thing that
  654. 49:43plays a big role is where the model is
  655. 49:45saved. Calculations on network drives
  656. 49:51can be significantly slower than
  657. 49:52calculations on a local hard drive,
  658. 49:55depending on the network. I would
  659. 50:00recommend that you save the model
  660. 50:02locally, especially for earthquake
  661. 50:04analyses. As already mentioned, we will
  662. 50:11hold the second part of this webinar on
  663. 50:13Friday, March 30th. March, on the
  664. 50:19evaluation of earthquake loads; on
  665. 50:21February 23rd. February. we will insert
  666. 50:31another webinar on moving loads in
  667. 50:32between. I hope that we will see each
  668. 50:37other again on that occasion. I thank
  669. 50:42you for your attention and wish you a
  670. 50:44nice Friday.

About this transcript

This page contains the full transcript of AxisVM | Erdbebenberechnung, Teil 1 [de] by Ingware AG, generated from the public captions YouTube serves with the video. The transcript has 4,235 words across 670 segments, with the original timestamps preserved so you can click any line to jump to that moment in the embedded player.

What you can do with it

Use the transcript to take notes, quote the speaker, build a study guide, generate a summary with ChatGPT or Claude via the YouTube Summary tool, or export it as a timed subtitle file with YouTube to SRT. You can also re-open it in the transcriber to choose a caption track available on the video.

Free YouTube transcript tool

YouTube2Text is a free YouTube transcript generator — no signup, no daily limit. Paste any YouTube link and get the full transcript instantly, with timestamps, click-to-jump, caption language selection, AI prompts for ChatGPT, Claude, and Gemini, and exports to TXT, SRT, VTT, or Markdown.